TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
47 / 110
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 2147483647
0
Table 115: Entry Description (20A4
h
)
4.2.32
Object 20A5
h
: Smart Energy Threshold Speed
The CoolStep™ functionality will be enabled when the actual speed is above this speed. It will be disabled
again when the actual speed drops below this value.
Object Description
Index
Name
Object Type
Data Type
20A5
h
Smart Energy Threshold Speed
Variable
UNSIGNED32
Table 116: Object Description (20A5
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 2147483647
0
Table 117: Entry Description (20A5
h
)
4.2.33
Object 2100
h
: Home Offset Display
This object shows the home offset. The value is given in microsteps.
Object Description
Index
Name
Object Type
Data Type
2100
h
Home Offset Display
Variable
SIGNED32
Table 118: Object Description (2100
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
ro
no
-2147483648. . . 2147483647
0
Table 119: Entry Description (2100
h
)
4.2.34
Object 2101
h
: Actual Load Value
This object shows the actual load value used for stall detection (StallGuard2™).
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at