background image

TS4 连接器安装手册 TS4 Connector Installation Manual

 

 

1.

 

安全说明

  Safety Instruction 

该产品只能由有相应资质的或经过专家培训的专业人员安装,安装过程中需要遵守所有安全

规范。天合光能不承担对于因不遵守这些警告而产生的任何责任。

 

The  products  may  be  installed  only  by  suitably  qualified  and  trained  specialists  with  due 

observance  of  all  applicable  safety  regulations.  Trina  Solar  declines  any  liability  in  the  event  of 

failure to observe these warnings. 

1.1

 

警告

  Warning 

1.1.1

 

仅可使用天合光能指定的零件和工具。对于自行装配,请务必遵守本文所述的

准备和安装的说明,否则天合光能不予保证对于产品的安全性及技术参数的一

致性。对于产品请勿做任何形式的修改。

 

Use only  the components and tools specified by Trina Solar. Do not deviate from 

the preparation and assembly procedures described here, since in this event, in the 

situation  of  self-assembly,  no  guarantee  can  be  given  as  to  safety  or  conformity 

with the technical data. Do not modify the product in any way. 

1.1.2

 

必须与天合认可的连接器相连接,否则天合光能不承担任何责任。

 

Connector must be mated with connector qualified by Trina, otherwise Trina Solar 

will disclaim any responsibility. 

1.1.3

 

不能在有负载的情况下插拔连接器。

Do Not Disconnect under Load. 

1.2

 

通用安全

  General Safety 

1.2.1

 

确认终端产品有防电击功能并确认其使用者采取了防电击措施。

 

Protection from electric shock must be assured by the end product and its user. 

1.2.2

 

为防止电击,在安装和拆卸连接器时必须断开电源。

 

To prevent electric shock, must be disconnected when the connector is installed and 

disassembled. 

1.2.3

 

连接器不能承受持续的机械拉伸,电缆应该由电缆扎带固定。

 

The plug connection must not be subjected to continuous mechanical tension. The 

cable should be fixed with cable binders. 

1.2.4

 

产品不得在含有烃、酚、酮、氨合物等与塑料有腐蚀的环境中使用。安装过程

中,禁止在连接器里添加或涂抹任何油脂及润滑剂。

 

Summary of Contents for 70900350

Page 1: ...TS4 TS4 Connector Installation Manual 1 File No TS IM TS4 1 Version 01 Date 2017 12 18...

Page 2: ...6 3 Product Selection Form 7 4 Connector Appearance Size Drawing 7 4 1 Positive Connector 7 4 2 Negative Connector 8 5 Installation 9 5 1 Requirements of Tools 9 5 2 Assembly Steps 11 6 Connecting an...

Page 3: ...s event in the situation of self assembly no guarantee can be given as to safety or conformity with the technical data Do not modify the product in any way 1 1 2 Connector must be mated with connector...

Page 4: ...core double insulation and insulating material is XLPE Trina prohibits the use of either untinned cable PVC cables otherwise Trina Solar will disclaim any responsibility 1 3 2 Unmated plug connectors...

Page 5: ...wed to be stored with the affected chemicals The plug connectors should be installed in one year 1 3 6 Trina Solar has the rights to make certain correction for the printing errors improvements and in...

Page 6: ...ed impulse voltage 16KV Ambient temperature range 40 85 Contact resistance 0 5m Application degree Class A Protection class Class Pollution degree 2 Degree of Protection IP68 1m 1h mated IP2X unmated...

Page 7: ...42 4 7 6 0 4 0 6 0 12 10 70930046 70930047 70900354 TS4 M1 70930041 TS4 F2 70930085 5 6 6 8 TS4 M2 70930084 TS4 F3 70900351 6 0 6 6 TS4 M3 70900350 TS4 F4 70930044 6 0 7 2 TS4 M4 70930043 TS4 F5 70930...

Page 8: ...TS4 TS4 Connector Installation Manual 8 4 2 Negative Connector TS4 M1 TS4 M2 TS4 M3 TS4 M4 TS4 M5 TS4 M6...

Page 9: ...llation Manual 9 5 Installation 5 1 Requirements of Tools 5 1 1 Wire Stripper 70930046 70930049 70930046 70930049 P N Jaw Crimping Range 70930046 Middle 4 0mm2 12AWG Right side 6 0mm2 10AWG 70930049 R...

Page 10: ...47 P N Jaw Riveting Range Picture 70930047 Middle 4 0mm2 12AWG Right side 6 0mm2 10AWG 70930051 Adjustable 4 0 6 0 10 0mm2 8AWG 5 1 3 Plastic Spanner 1 set 2 pc P N 70900354 5 1 4 Tool Box P N 7093004...

Page 11: ...the insulating layer of cable L 6 0 5mm Be attention and not to cut off the individual strands 5 2 2 Inserting pin and socket 70930047 70930051 Place the metal terminal in the hole of the riveting too...

Page 12: ...eting tool handle and press it to the end to complete the riveting The cable tension after riveting is referenced to the following table All individual strands should be bandaged Cable specifications...

Page 13: ...2AWG TS4 F5 TS4 M5 6 6 0mm2 10AWG 8 10 0mm2 8AWG TS4 F6 TS4 M6 5 2 4 Pushing pin Insert the crimped on contact into the insulator until they engage Pull gently on the lead to check that the metal part...

Page 14: ...6 6 8mm TS4 F3 M3 6 0 6 6mm TS4 F4 M4 6 0 7 2mm TS4 F5 M5 7 2 8 7mm 1 0 X 1 8mm TS4 F6 M6 1 Note 1 Ensure the concentricity of cable and cable nut when you screw cable nut 2 pin Note 2 Make sure the n...

Page 15: ...er when it connected 7 Cable 7 1 Connection of Cable 20mm In order to avoid the cable sealing element deformation that a force generated by bending the wire the cable need keep at least 20mm straight...

Page 16: ...ed Kingdom 44 1332 63 8799 EUservice trinasolar com Richtistrasse 11 8304 Wallisellen Switzerland 41 43 299 6800 Einsteinring 26 85609 Aschheim Germany 49 89 1228 49250 C Caleruega 79 3 A 28033 Madrid...

Reviews: