Ethernet communicator E10Tv2 

3.5

 

Reporting → Alarm Receiving Centre (ARC) reporting 

Reporting → Primary and backup settings 

 

To have connection with Primary and Backup mark checkboxes Enable.  

 

Fill in fields for Remote Host, Remote Port.  

 

Choose reporting protocol TCP or UDP. 

 

Enable PING Time and set time between signals in seconds.  

 

Enter Encryption key (six-symbol hexadecimal number).  

3.6

 

Reporting → Protegus service 

Protegus service allows users to remotely monitor and control the communicator. 
Protegus service allows simultaneous transmission of data to the Protegus server for Mobile/Web application. 
For more information about PROTEGUS service visit 

www.protegus.eu

 

Enable cloud service at Reporting → PROTEGUS service tab. 

 

Enter Service code (default code – 123456), for more safety change it to 6-symbol authentication code

This code is used, when adding new system to the application. 

Figure 5. ARC Reporting window

 

Figure 6. Protegus service window

 

Summary of Contents for E10Tv2

Page 1: ...Ethernet communicator E10Tv2 USER MANUAL UAB TRIKDIS Draugyst s str 17 LT 51229 Kaunas LITHUANIA E mail info trikdis lt Webpage www trikdis lt...

Page 2: ...PANEL 5 CONFIGURATION AND OPERATION 6 3 1 MAIN STEPS TO CONFIGURE COMMUNICATOR VIA USB CABLE 6 3 2 MAIN STEPS TO CONFIGURE COMMUNICATOR REMOTELY 6 3 3 TRIKDISCONFIG BASICS 7 3 3 1 Main action buttons...

Page 3: ...ion to control panels via TLC terminal connection Communications Communication modes Ethernet Communicator transfers all messages from control panel in Contact ID codes Simultaneous event reporting to...

Page 4: ...other household waste 1 2 Technical Parameters Parameter Description Power supply voltage DC 12 6 3 V Current consumption 120 mA stand by Up to 250 mA transmitting Ethernet connection IEEE802 3 10 Bas...

Page 5: ...control panel Power displays power supply status and the functioning of the microprocessor Green flashing Power supply is sufficient Yellow flashing Power supply is not sufficient 11 5 V Installation...

Page 6: ...onfig program to communicator 3 2 Main steps to configure communicator REMOTELY Make sure that the communicator is connected to supply source and is operating 1 Start TrikdisConfig software 2 At the f...

Page 7: ...To read about communicator s functionality and how to configure specific parameters click Help F1 and from the program menu select the section This will open an appropriate chapter from the user manu...

Page 8: ...is section Settings Ethernet settings Enter Internal MAC When Use DHCP checkbox is selected module registration in the network will be done automatically o If automatic registration is unsuccessful en...

Page 9: ...ymbol hexadecimal number 3 6 Reporting Protegus service Protegus service allows users to remotely monitor and control the communicator Protegus service allows simultaneous transmission of data to the...

Page 10: ...changed manually After an update all the previous communicator parameters will remain the same When writing firmware manually it can be changed to a newer or older version To update 1 Run TrikdisConf...

Page 11: ...E10Tv2 can be controlled remotely using TrikdisConfig software To do so follow steps below 1 Open TrikdisConfig 2 At the field Remote access in the field Unique ID enter the MAC address MAC address i...

Page 12: ...ivations refer to chapter 3 7 Event Summary NC Normally Closed NO Normally Open EOL End of line Performance test 1 After configuration and installation is complete perform a system test Activate an ev...

Reviews: