background image

 

 

 

 

 

©1997-2017 Trikdis  

2  

www.trikdis.com  

 

Ethernet communicator E10Tv2 

Contents 

 

DESCRIPTION ................................................................................................................................... 3

 

1.1

 

S

AFETY 

R

EQUIREMENTS

 ................................................................................................................................ 4

 

1.2

 

T

ECHNICAL 

P

ARAMETERS

 .............................................................................................................................. 4

 

1.3

 

P

ACKAGE 

C

ONTENTS

 .................................................................................................................................... 4

 

1.4

 

C

OMMUNICATOR STRUCTURE

 ........................................................................................................................ 4

 

1.5

 

T

ERMINAL BLOCK DESCRIPTION

 ....................................................................................................................... 5

 

1.6

 

L

IGHT INDICATION

 ........................................................................................................................................ 5

 

 

INSTALLATION PROCESS ................................................................................................................... 5

 

2.1

 

P

ROGRAM SECURITY CONTROL PANEL

 .............................................................................................................. 5

 

 

CONFIGURATION AND OPERATION ................................................................................................... 6

 

3.1

 

M

AIN STEPS TO CONFIGURE COMMUNICATOR VIA 

USB

 

CABLE ........................................................................... 6

 

3.2

 

M

AIN STEPS TO CONFIGURE COMMUNICATOR 

REMOTELY ................................................................................. 6

 

3.3

 

T

RIKDIS

C

ONFIG 

B

ASICS

 ................................................................................................................................. 7

 

3.3.1

 

Main action buttons ....................................................................................................................... 7

 

3.3.2

 

Status bar ....................................................................................................................................... 7

 

3.3.3

 

Restore default settings .................................................................................................................. 7

 

3.4

 

S

YSTEM SETTINGS

 ........................................................................................................................................ 8

 

3.5

 

R

EPORTING 

 

A

LARM 

R

ECEIVING 

C

ENTRE 

(ARC)

 REPORTING

 ............................................................................. 9

 

3.6

 

R

EPORTING 

 

P

ROTEGUS SERVICE

 ................................................................................................................. 9

 

3.7

 

E

VENT 

S

UMMARY

 ...................................................................................................................................... 10

 

3.8

 

F

IRMWARE UPDATE

 .................................................................................................................................... 10

 

 

REMOTE CONTROL ......................................................................................................................... 11

 

 

WIRING.......................................................................................................................................... 12

 

5.1

 

W

IRING  DIAGRAM

 ..................................................................................................................................... 12

 

5.2

 

I

NPUT CONNECTION

 ................................................................................................................................... 12

 

 

PERFORMANCE TEST ...................................................................................................................... 12

 

 

 

 

 

 

 

 

 

Summary of Contents for E10Tv2

Page 1: ...Ethernet communicator E10Tv2 USER MANUAL UAB TRIKDIS Draugyst s str 17 LT 51229 Kaunas LITHUANIA E mail info trikdis lt Webpage www trikdis lt...

Page 2: ...PANEL 5 CONFIGURATION AND OPERATION 6 3 1 MAIN STEPS TO CONFIGURE COMMUNICATOR VIA USB CABLE 6 3 2 MAIN STEPS TO CONFIGURE COMMUNICATOR REMOTELY 6 3 3 TRIKDISCONFIG BASICS 7 3 3 1 Main action buttons...

Page 3: ...ion to control panels via TLC terminal connection Communications Communication modes Ethernet Communicator transfers all messages from control panel in Contact ID codes Simultaneous event reporting to...

Page 4: ...other household waste 1 2 Technical Parameters Parameter Description Power supply voltage DC 12 6 3 V Current consumption 120 mA stand by Up to 250 mA transmitting Ethernet connection IEEE802 3 10 Bas...

Page 5: ...control panel Power displays power supply status and the functioning of the microprocessor Green flashing Power supply is sufficient Yellow flashing Power supply is not sufficient 11 5 V Installation...

Page 6: ...onfig program to communicator 3 2 Main steps to configure communicator REMOTELY Make sure that the communicator is connected to supply source and is operating 1 Start TrikdisConfig software 2 At the f...

Page 7: ...To read about communicator s functionality and how to configure specific parameters click Help F1 and from the program menu select the section This will open an appropriate chapter from the user manu...

Page 8: ...is section Settings Ethernet settings Enter Internal MAC When Use DHCP checkbox is selected module registration in the network will be done automatically o If automatic registration is unsuccessful en...

Page 9: ...ymbol hexadecimal number 3 6 Reporting Protegus service Protegus service allows users to remotely monitor and control the communicator Protegus service allows simultaneous transmission of data to the...

Page 10: ...changed manually After an update all the previous communicator parameters will remain the same When writing firmware manually it can be changed to a newer or older version To update 1 Run TrikdisConf...

Page 11: ...E10Tv2 can be controlled remotely using TrikdisConfig software To do so follow steps below 1 Open TrikdisConfig 2 At the field Remote access in the field Unique ID enter the MAC address MAC address i...

Page 12: ...ivations refer to chapter 3 7 Event Summary NC Normally Closed NO Normally Open EOL End of line Performance test 1 After configuration and installation is complete perform a system test Activate an ev...