Cellular security control panel CG17
3.
Connect the
CG17
to a computer using a USB Mini-B cable.
4.
Launch the configuration program
TrikdisConfig
. The program will automatically recognize the connected device and will
automatically open the
CG17
configuration window.
5.
Click the
Read [F4]
button to see the current parameters of the
CG17
. If prompted, enter the
administrator
or
installer
code in the pop-up window.
Description of TrikdisConfig status bar
Once the
CG17
is connected to the
TrikdisConfig
software, the program will display information about the connected device in
the status bar:
Status bar
Name
Description
IMEI/Unique ID
The device’s IMEI number
Status
Operational state
Device
Device type (must show
CG17
)
SN
Device’s serial number
BL
Bootloader version
FW
Device’s firmware version
HW
Device’s hardware version
State
Type of connection with the program (USB or remote)
Role
Access level (shown after access code is approved)
Note:
Click
Read [F4]
to make the program read and display the settings that are currently saved on the device.
Click
Write [F5]
to save the settings displayed on the screen to the device.
Click
Save [F9]
to save the settings to a configuration file. You can upload the saved settings to other devices
later. This allows to quickly configure multiple devices with the same settings.
Click
Open [F8]
and choose a configuration file to view previously saved settings.
If you want to revert to the default settings, click the
Restore
button at the lower left of the screen.
When the
Read [F4]
button is clicked, the program will read and show settings currently saved on the
CG17
. With
TrikdisConfig
,
set the required parameters using the following program window descriptions
.