Cellular security control panel CG17
Siren squak on arm/disarm
– the siren will make a short sound once when the alarm is armed and twice when it is
disarmed.
Entry time
– time for entering through the “
Delay
” zone. Time is anywhere from 0 to 999 seconds.
Exit time
–time for exiting through the „
Delay
” zone. Time is anywhere from 0 to 999 seconds. When the alarm is armed
using the
Protegus
app or phone call, the system will not count the
Exit time
.
Keyswitch
sets the alarm’s arm/disarm mode using the “
Keyswitch
”
zone
.
You can choose control using
Pulse
or
Level.
“Access” tab
Settings group “Access codes”
Administrator Code
–
(default code - 123456)
gives full access to configuration (the code must be 6 symbols long; it must
consist of latin letters and/or numbers).
SMS password –
(default code - 123456)
is for safety when controlling with SMS messages. To ensure more safety, change
it to a 6-symbol code only you know.
Installer Code
– (
default code - 654321
) gives the installer access to configuration. To ensure safety, change it to a 6-
symbol code only you know.
Note:
If the default
administrator code
is set (123456), the software will not require it to be entered and clicking
Read [F4]
will immediately show the parameters currently saved on the device.
Settings group “Installer permissions”
For setting installer’s rights.