Cellular security control panel CG17
Numerical code of
event message
Event message meaning
Numerical code of
event message
Event message meaning
From 73 to 80
Restore. Temperature of sensor (1-
8) up to normal
120
Danger! GSM jamming!
From 81 to 88
Malfunction. No contact with
sensor (1-8)
121
Restore after GSM jamming
From 89 to 96
Restore. Contact with sensor (1-8)
122
Arming of alarm
From 97 to 104
Malfunction. No connection to
RS485 module (1-8)
From 123 to 134
Bypass of zone (1-12)
From 105 to 112
Restore. Connection with RS485
module (1-8)
From 135 to 146
Bypass of zone (1-12) inactive
Setting parameters remotely
IMPORTANT:
Remote configuration will only work when:
1.
The
Protegus
cloud
service is enabled. Turning on the service is described in chapter
33.4“Users &
Reporting“ window
(
settings group „PROTEGUS cloud“
);
2.
An activated SIM card is inserted and the PIN code is entered or disabled;
3.
The power is on (“POWER” LED is green solid);
4.
Is connected to the network (“NETWORK” LED is green solid and blinks yellow).
1.
Download the software
TrikdisConfig
from www.trikdis.com
2.
Make sure that the controller is connected to the Internet and that connection with
Protegus
is enabled.
3.
Launch the configuration software
TrikdisConfig
and in the
Unique ID
field of the
Remote Access
group enter the IMEI
number of your
CG17
(the IMEI number can be found on stickers on the back of the device and on the packaging).
4.
In the field
System Name
give a name to the
CG17
with this IMEI. Click
Configure
.
5.
Click the button
Read [F4]
and the program will read the parameter values currently set on the
CG17
. If a window for
entering the
Administrator code
appears, enter the 6-symbol
administrator
code. If you want the program to remember
the code, tick the box next to
Remember password
and click the button
Write [F5]
.
6.
Make the desired changes to the settings of the
CG17
and click
Write [F5]
. If you want to disconnect from the
CG17
click
Disconnect
and exit the
TrikdisConfig
program.
Testing of the installation
When configuration and installation are finished, test the system:
1.
Check if the power is on;
2.
Check the network connectivity (NETWORK indicator): sufficient GSM signal strength is level 5 (green solid for 4 seconds
and five yellow flashes). Sufficient 3G signal strength is level 3 (green solid for 4 seconds ant three yellow flashes). If the
red TROUBLE light blinks 5 times, find another place to mount the
CG17
;
3.
To test the
CG17
’s
inputs, enable them and check if the correct messages reach the recipients;
4.
To test the
CG17
’s outputs, activate them remotely and check if the correct messages reach the recipients and the outputs
are activated correctly;
5.
Test the alarm to make sure that the central monitoring station accepts the events correctly.