2.2 

reference for nomination 

 

After  unpacking  at  first  please  check  the  equipment  upon  damages  caused  by 
transnport. If you should find a damage please connect immediately your distributer. 
After that please control the content of the cardboard-box: 
Besides the 

TRV-100 

you should find the following parts: 

 
 

- Power-cable 

 

- IR-remote-control-unit 

 

- operating-instructions 

 

- warrantee-sheet 

 

 
Install  the  equipment  horizontally  at  a  dry  place.  Always  take  care  for  good  airing. 
Strong magnetic strayfield which can be caused by power amplifier tansformers and 
Halogen light transformer

 

can lead to hum and noise. Therefore pleas install the  pre-

amplifier in a distance to such equipments. Also the connecting cables shouldn't be 
installed  parallel  to  light-lines.  Hum  and  noise  are  also  caused  by  luminious 
discharge lamps so that therefrom should be a distance of about 1 m at least. . 
Avoid  direct  sunlight  and  install  do  not  install  the 

TRV-100

 

next  to  powerful  heating 

units. 
 
 
 
 

2.3 

Warrantee and Service 

 

With  the 

TRV-100 

you  bought  a  product  of  hight  quality,  with  a  well  developed 

technology.  
Your 

TRIGON

-Team takes care that in each stage of production the demands on a 

TRIGON

-product can be assured by several quality-tests and a severe control before 

sending-off  the  products.  Should  there  be  nevertheless  a  fault, 

TRIGON-

ELEKTRONIK  GmbH

  offers  a  guarantee  of  3  years.The  guarantee  consists  of  the 

repair  of  the  defect  parts  as  well  as  the  wage.  Further  demands  are  excluded.  The 
guarantee  excludes  any  damage  caused  by  inexpert  installation,  incorrect  handling 
or repairs by not authorized distributers or private persons. Further the guarantee will 
expire  if  the  identify-numbers  are  made  unrecognizable  as  well  as  in  the  case  of 
damages caused by accident or transport-damages. 
 

Summary of Contents for TRV-100

Page 1: ...1 OPERATING INSTRUCTIONS FOR PRE AMPLIFIER TRV 100 INPUT RECORD SPLIT OUT 1 OUT 2 MODE...

Page 2: ...e recorder etc 4 4 Possibilities for copying between two recording equipments 4 5 The outputs 4 6 Remote socket 4 7 Connection of the equalizers 4 8 Connection to a surround system 5 The function MODE...

Page 3: ...sub socket For the running of a high ohmic head phone there is a 6 3 mm phone plug at the front of the equipment Further the TRV 100 has got an input output where special equipment like Surround Deco...

Page 4: ...fier shouldn t be settled directly in the sun light Please take care for good air circulation at the place where the equipment is installed Never spill any liquid onto the pre amplifier Liquids are no...

Page 5: ...luminious discharge lamps so that therefrom should be a distance of about 1 m at least Avoid direct sunlight and install do not install the TRV 100 next to powerful heating units 2 3 Warrantee and Ser...

Page 6: ...ed for ca 5 seconds If working at the cabling in any case you should switch off theTRV 100 as well as the rest of the system As a help please pay attention to the cabling expample at top 4 7 and the f...

Page 7: ...ng as long as the MODE Menue is active With short strikes you will get to each top of the menue A longer strike will store the chosen positions The MODE Signal isn t gleaming while storing As soon as...

Page 8: ...rted signal 17 OUTPUT 1 This is the assymmetrical output of the pre amplifier Hereon a power amplifier or a active box with assymetrical inputs can be connected There is no uninverted signal 18 SPLIT...

Page 9: ...s they need an additonal amplifier stage Nevertheless special Phono pre amplifiers for record players can be connected to these inputs 21 BALANCED INPUTS INPUT 1 as well as INPUT 2 is produced as symm...

Page 10: ...r advices for the MODE Menue in chapter 5 Button 0 With this button the amplifier will be switched to Mute that means that the volume is zero Instead of the INPUT and Volume numbers you will see horiz...

Page 11: ...nal voltage between 0 2 voltage and 2 voltage Such units are for example Tuner CD Player with integrated DA converter tape recorders cassette players HIFI Video recorders etc Effect units like equaliz...

Page 12: ...metrical output is good to use in the case of very long connection cables between pre amplifier and amplifier The advantage of a symmetrical cabling is that jammings going on to such lines will be eff...

Page 13: ...nels front left and front right have to be connected to the sockets of SPLIT INPUT 18 By pressing the button SPLIT the main speakers are now connected to the surround decoder by using the main power a...

Page 14: ...to a further function after the 6th pressing you will leave the MODE Menue If you want to store an adjustment for a longer time you ll have to keep the MODE button pressed for an instand During this...

Page 15: ...stment you can store it durably as described above By using the MODE button another time you ll jump to the next menue But if you don t want to adjust any more the amplifier will leave the MODE menue...

Page 16: ...The TRV 100 has got an elctronial volume adjustment This operation offers a better reproduce quality in comparison to a convenient Potentiometers and advantageous extra functions One of them is the a...

Page 17: ...tched on at the same time as the pre amplifier Sometimes it can be an advantage to switch off this remote voltage That happens for instance if listening only by head phones and the power amplifier isn...

Page 18: ...y into the socket Is the used socket connected to the AC voltage or is it connected to the home fuse box Check the home fuse box Did the internal fuse blow Send the equipment to the service 6 2 nothin...

Page 19: ...he moment Press the button PREAMP on the remote control unit Now the remote control unit is activated for the pre amplifier Are the batteries finished Put in new batteries Is the distance too great De...

Page 20: ...g Inputs 6x Cinch 2x XLR Outputs 1x Cinch 1x XLR 2x Cinch Tape Head phone output 1x Phone Jack 6 3mm 200 Ohm Additional equipment IR remote control unit Guarantee 3 years Modifications are reserved Pr...

Reviews: