www.tridonic.com
13
Subject to change without notice. Information provided without guarantee.
Data sheet 03/20-EM042-21
Emergency lighting units
EM powerLED
5. Electrical data
Automatic circuit breaker type
C10
C13
C16
C20
B10
B13
B16
B20
Inrush current
Installation Ø
1.5 mm
2
1.5 mm
2
2.5 mm
2
2.5 mm
2
1.5 mm
2
1.5 mm
2
2.5 mm
2
2.5 mm
2
I
max
time
EM powerLED BASIC FX 103 SR 50W 50V
20
30
40
50
16
24
32
40
6.6 A
30 μs
EM powerLED BASIC FX 104 SR 50W 50V
20
30
40
50
16
24
32
40
6.6 A
30 μs
Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %
Type
THD
3
5
7
EM powerLED BASIC FX 103 SR 50W 50V
6.5 %
4.5 %
2 %
1 %
EM powerLED BASIC FX 104 SR 50W 50V
6.5 %
4.5 %
2 %
1 %
5.1 Maximum loading of automatic circuit breakers
5.2 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %
5.3 Insulation matrix
Mains
Switched Live
C/F
L link
Battery, LED, Test
switch, Indicator LED
I-SELECT 2
Mains
–
•
•
•
• •
•
Switched Live
•
–
•
•
• •
•
C/F
•
•
–
•
• •
•
L link
•
•
•
–
• •
•
Battery, LED, Test
switch, Indicator LED
• •
• •
• •
• •
–
• •
I-SELECT 2
•
•
•
•
• •
–
• Represents basic insulation
• • Represents double or reinforced insulation