Tridonic 87500975 Manual Download Page 9

www.tridonic.com

9

Subject to change without notice. Information provided without guarantee.

Data sheet 11/21-LC888-6

LED Driver

Linear fixed output

Setting the daylight sensor (4. code switch)

Setting the standby dimming (5. code switch)

Setting the second-order delay (6. code switch)

4. Functions

4.1 Process diagram when power on

2

3

Hold time

5 s (default)

90 s

300 s

600 s

4

Daylight sensor

30 lux (default)

disable

5

Standby dimming

10 % (default)

30 %

6

Second-order delay

 (default)

10 min

1

Sensitivity

100 % (default)

50 %

Setting the detection area (1. code switch)

Setting the hold time (2. and 3. code switch)

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

4.2 Adjustable code switch setting

Initialization

process

Night

Night

Daytime

Daytime

ON

OFF

0s 5s 6s11s 12s

Ts

T+4s

T+1s

Ts

T+4s

T+1s

Ts

T+4s

T+1s

Ts

T+4s

T+1s

100% PWM

100% PWM

100% PWM

100% PWM

100% PWM

0% PWM

0% PWM

0% PWM

10–30% PWM

10–30% PWM

10–30% PWM

10–30% PWM

10–30% PWM

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Invalid

trigger

Trigger

valid

Trigger

valid

Trigger

valid

Trigger

valid

Continuous

trigger valid

Continuous

trigger valid

Continuous

trigger valid

Continuous

trigger valid

Model

ON / OFF

Timing

Output

Monitor

Power losses on stand-by

system < 1 W

Power losses on stand-by

system < 1 W

•  In this sequence diagram, the default state of dialing is all ON state.
•  When the PWM output signal changes from 100 % to 10 % or 30 %, the gradual change time is 1 s, followed by a blocking time of about 3 s,  
  during which there is no induction.
•  T = the set delay time (5 s, 90 s, 300 s, 600 s) and start timing with the last valid trigger.
•  Within 20 s after turning on, once daylight is detected, turn off the light directly. After that, there will be a 10-minute photosensitive threshold judgment.  
  If the daylight continues to be detected, it will finally be judged as daytime mode, and the daytime mode induction is invalid.
•  When night changes to day, it also needs to pass 10 minutes of photosensitivity threshold before it is judged as day mode.  
  When day changes to night, it only takes 3 s to trigger directly.
•  When the 6. digit dialing status is OFF, if the output signal is 10 % or 30 % PWM and there is no human sensing within 10 minutes,  
  the output signal will become 0 % PWM.

DIP switch factory settings all default ON state.
Set the DIP switch only after mains off.
Hot plug-in is not permitted when connecting sensors.

Summary of Contents for 87500975

Page 1: ...nt 350 300 250 and 200 mA Max output power 35 W Up to 87 efficiency Nominal life time up to 100 000 h 5 year guarantee conditions at www tridonic com Housing properties Casing Driver metal white Casing sensor polycarbonat white Type of protection IP20 Functions Overload protection Short circuit protection No load protection È Technical data LED Driver page 3 Product description LED Driver page 4 6...

Page 2: ...etween L N 1 kV Mains surge capability between L N PE 2 kV Surge voltage at output side against PE 4 kV Life time up to 100 000 h Guarantee conditions at www tridonic com 5 years Dimensions L x W x H 230 x 30 x 21 mm Hole spacing D 218 mm Driver LC 35W 200 350mA stepDIM lp SNC essence series non SELV stepDIM 230 21 122 4 tc 4 30 218 ø4 1 tc 16 2 side fixing feature Ordering data Type1 Article numb...

Page 3: ...n angle 150 Max detection area1 ø 14 m Max mounting height 6 m tc 70 C Ambient temperature ta 20 70 C Storage temperature ts 20 70 C Humidity min 5 max 95 Type of protection IP20 Protection class Protection class II Casing material PC halogen free Casing colour White Dimensions L x W x H 89 x 15 8 x 12 1 mm Hole spacing D 84 mm Motion Sensor included Automatic switching based on motion and light l...

Page 4: ...Driver can be earthed via metal housing If the LED Driver will be earthed protection earth PE has to be used There is no earth connection required for the functionality of the LED Driver Earth connection is recommended to improve following behaviour Electromagnetic interferences EMI Transmission of mains transients to the LED output In general it is recommended to earth the LED Driver if the LED m...

Page 5: ...0 100 12 10 2 4 6 8 Load THD 82 85 86 84 83 87 88 89 90 30 50 70 60 80 90 40 100 Load Efficiency 0 75 0 80 0 90 0 85 0 95 1 00 30 60 50 70 80 90 40 100 Load Power factor 0 50 80 70 90 60 50 30 40 100 5 15 10 25 20 40 45 35 30 Load Input power W 0 210 80 70 90 60 30 40 50 100 180 150 120 90 60 30 Load Input current mA 3 8 Current setting 200 mA Switch 1 Off Switch 2 Off 350 mA Switch 1 On Switch 2 ...

Page 6: ...f the product is used outside a luminaire the installation must provide suitable protection for people and environment e g in illuminated ceilings Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1 5mm2 1 5mm2 1 5mm2 2 5mm2 1 5mm2 1 5mm2 1 5mm2 2 5mm2 Imax Time LC 35 200 350 121 stepDIM lp SNC 36 47 58 73 36 47 58 73 12 A 80 µs THD 3 5 7 9 11 LC 35 200 3...

Page 7: ...anti interference ability it is not affected by temperature humidity airflow dust noise brightness and other factors Avoid installing metal accessories or shells metal will block the microwave and affect the effect The antenna surface should avoid large current circuit coverage which may cause interference The photosensitive position should avoid being blocked by opaque objects which will change t...

Page 8: ...trate the metal is close to the RF hollow width of the lamp board or alu minum substrate is required as follows 1 When the thickness of the baffle plate and the aluminum substrate all the metal part is D 1 mm the suggested hollow length is 80 mm width 13 mm 2 When the thickness of the baffle plate and the aluminum substrate all the metal part is 1 mm D 2 mm the suggested hollow length is 80 mm wid...

Page 9: ...Continuous trigger valid Continuous trigger valid Continuous trigger valid Continuous trigger valid Model ON OFF Timing Output Monitor Power losses on stand by system 1 W Power losses on stand by system 1 W In this sequence diagram the default state of dialing is all ON state When the PWM output signal changes from 100 to 10 or 30 the gradual change time is 1 s followed by a blocking time of about...

Page 10: ...devices in accordance with the WEEE directive to suitable recycling facilities h d Take 3 m as an example the detected moving target person is approx 170 cm high and weighing approx 65 kg In the test room the module is installed with the antenna facing down and the person is moving in the direction of the sensor at a speed of 1 m s A person moved towards the sensor with a speed of 1 m s during the...

Reviews: