Communication
TCD Electronics | Function Manual | Version: TCD_PROFI_S_EN_200326_E003
31
Index Parameter name
Data type
[size]
Access Annotation
23
TOTAL_UNITS
Unsigned16 Read
Write
Influences the TOTAL,TOTAL_DOUBLE and
PRESET_TOT value.
The INPUT_SELECTOR defines the available physical
unit codes that are allowed e.g. INPUT_SELECTOR is
set to mass flow, the TOTAL_UNITS only accepts
mass units.
Available Mass units:
1088: kg
1089: g
1090: mg
1091: Mg
1092: t
1093: oz
1094: lb
1095: STon
1096: T
1567: ct
1568: lb (tr)
1569: oz (tr)
1995: customized unit
Available Volume units:
1034: m³
1035: dm³
1036: cm³
1037: mm³
1038: l
1039: cl
1040: ml
1041: hl
1042: in³
1043: ft³
1044: yd³
1045: mile³
1048: gal
1046: pint
1047: quart
1049: i.gal
1050: bush
1051: BBL
1052: BBL (liq)
1517: kl
1570: fl oz (US)
1572: af
1641: BBL (fed)
1995: customized unit
Available Standard volume units:
1053: Sft³