Communication
TCD Electronics | Function Manual | Version: TCD_PROFI_S_EN_200326_E003
22
Index Parameter name
Data type
[size]
Access Annotation
77
VOLUME_FLOW_H
I_LIMIT
Float32
Read
Volume flow high limit
78
MASS_FLOW
101
Read
Mass flow
79
MASS_FLOW_UNIT
S
Unsigned16 Read
Write
Mass flow units:
The coding is according the PROFIBUS PA Profile
specification:
1318: g/s
1319: g/min
1320: g/h
1321: g/d
1322: kg/s
1323: kg/min
1324: kg/h
1325: kg/d
1326: t/s
1327: t/min
1328: t/h
1329: t/d
1330: lb/s
1331: lb/min
1332: lb/h
1333: lb/d
1334: STon/s
1335: STon/min
1336: STon/h
1337: STon/d
1338: T/s
1339: T/min
1340: T/h
1341: T/d
1606: oz/s
1607: oz/min
1608: oz/h
1609: oz/d
1995: customized unit
80
MASS_FLOW_LO_L
IMIT
Float32
Read
only
Mass flow low limit
81
MASS_FLOW_HI_LI
MIT
Float32
Read
only
Mass flow high limit
82
DENSITY
101
Read
only
Process value
83
DENSITY_UNITS
Unsigned16 Read
Write
Density unit
The coding is according the PROFIBUS PA Profile
specification:
1097: kg/m³
1098: Mg/m³
1099: kg/dm³
1100: g/cm³
1101: g/m³