16
Electrical connections
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in
accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This hob is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this
book.
The hob is supplied with a 3 core flexible supply cord
incorporating a 3amp plug fitted. In the event of
having to change the fuse, a 3amp ASTA approved
(BS 1362) fuse must be used.
Should the plug need to be replaced for any reason,
the wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow - Earth
Blue
- Neutral
Brown
- Live
— Connect the green and yellow (earth) wire to
the terminal in the plug which is marked with
the letter 'E' or the earth symbol
or
coloured green and yellow.
— Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N'
or coloured black.
— Connect the brown (live) wire to the terminal
in the plug which is marked with the letter 'L'
or coloured red.
NOTE:
The earth wire should be about 2 cm. longer
than the live and neutral wires.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
Permanent Connection
In the case of a permanent connection, it is necessary
that you install a double pole switch between the hob
and the electricity supply (mains), with a minimum
gap of 3 mm. between the switch contacts and of a
type suitable for the required load in compliance with
the current electric regulations.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
FO 0390
☞
Summary of Contents for TBG 640
Page 2: ......
Page 17: ...17 B L N 0 1 2 3 4 220 240 A Wiring diagram A IGNITOR SWITCH B IGNITOR UNIT ...
Page 22: ......