12
Ignition HT Spark
Spark Generator
Ispra Control's BF 50046 - 230-240V 0.6 YA T 120
Spark Gap
Fixed
OVERALL DIMENSIONS
Width:
580 mm.
Depth:
500 mm.
Height:
88 mm.
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Aeration adjustment none
Instructions for the Installer
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
Thickness: 30 mm.
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE m
3
/h
0.286
0.057
0.190
0.038
0.095
0.028
NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE g/h
202
43.5
144
29
72
21,5
NOZZLE REFERENCE
86
40
71
32
50
28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Rear Left Burner (semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input
3.0 kW Natural Gas (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.
This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.
CLASS APPLIANCE: 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar
Rear Right Burner (semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input
1.0 kW (3412 BTU/HR)
Summary of Contents for TBG 640
Page 2: ......
Page 17: ...17 B L N 0 1 2 3 4 220 240 A Wiring diagram A IGNITOR SWITCH B IGNITOR UNIT ...