Pause time
h = 3
The pause time is 3 hours.
Number of cycles
c = 1
The number of cycles is one (1) stroke
during
the
dispensing
time.
The default settings in the Hour-Mode when using a FP4 B with one (1) lubricant
outlet result in an emptying time (service life) of 338 days (= 11 months) for a full 400ml
lubricant cartridge, provided that the FP4 B is permanently switched on and no speci-
al dispensations have been made. Within approx. 3 hours, the FP4 B will deliver one
donation per stroke (0.16 cm³).
If you use the FP4 B with one (1) lubricant outlet, a dispensing stroke will be deliver-
ed from one outlet at the end of the pause time. If you are using the FP4 B with two (2)
lubricant outlets, one delivery of one stroke per outlet will be delivered at the end of the
pause time. The pause time is doubled.
Verify that the default settings are appropriate for your application and that the lubri-
cation point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FP4 B with the default settings in the Hour-Mode
-h-.
If this is
not
the case, change the values for the dispensing time h and number of cy-
cles c accordingly; see chapter 6.3.8 for an explanation of how to make these changes.
To use FP4 B, it must first be properly mounted and installed and then switched on.
Installation is very simple and described in detail in chapter 5.2; switching on is descri-
If you order a special version of FP4 B from the factory, the information contained in
the supplement is authoritative for you!
6.2
Factory settings
The FP4 B is always delivered ex works with the following settings:
Operation mode Hour-Mode -h-
State
OFF
FP4 B is switched off
The factory settings foresee using the FP4 B in the Hour-Mode -h-. If you want to
operate the FP4 B in
Empty-Time-Mode Et
, you have to make changes in the SET-
Menu of the FP4 B, chapter 6.3.6.
6.2.1 Default settings Hour-Mode -h-