PRESTIGE SOLO & EXCELLENCE IGNITION KIT - INSTALLATION INSTRUCTIONS
1.6. Configuration Changes
1.6.1 Wiring
Following the printed circuit board replacement and
wiring changes, the ALARM relay function is no longer
available for the configurations that use it. Therefore,
anything wired to the Alarm relay needs to be rewired
to a different relay if required (see table below).
In some configurations, the Error function will
no longer be available. Please contact your
Triangle Tube assistance.
NOTICE
Preset
config
Page *
Connected
to
Reconnect
to
ACVMax setup (Flexible
pump config)
Remark
1
18
ALARM
FLAME
Flex. Relay 5 to be set to ERR :
FLAME: OFF
ERROR: ON
2
19
3
20
4
21
5
22
6
23
8
25
10/11**
24**
ALARM
Pump 3
Flex Relay 3 to be set to
MIX OPEN:
MIX OPEN: ON
ONLY if no additional pump is con-
nected to Flex Relay 3 (P3).
If a pump is connected, please con-
tact your TTP assistance.
7
-
Error function not available anymore
9
26
Error function not available anymore
10
27
These configurations are no longer available (no available relay for the motor open function that was
implemented by the Error relay). Please contact your TTP assistance.
11
28
12
29
13
30
Error function not available anymore
* refer to the manual “Prestige Control Application Supplement - ACVMax”, 2015-10
** The configuration mentioned on this page in the manual is mistakenly identified 7. It should be 11 (or possibly 10)
1.6.2 CTRLMax Setup
Additionally, the setting of the relevant Flex relays needs
to be adapted through the Installer menu, as indicated
on the next page.