Pre-Installation Items
3
LOCATION / MOUNTING CONSIDERATIONS
This water heater is not intended for outdoor installations
Maintain minimal piping distance between the boiler and
the water heater to:
-
Reduce piping heat loss
-
Provide minimal friction loss
Locate water heater in a manner that any leakage from
the heater or water connections will not cause damage
to the area adjoining the water heater or to lower floors
in the structure. When such a location is unavoidable, a
suitable drain pan with adequate drainage should be
placed under the water heater.
The Mini SMART water heater is designed for verti-
cal installation only.
RECOMMENDED CLEARANCES
Install the water heater allowing adequate clearances for
servicing.
Recommended top and bottom vertical clearances is 12
inches minimum for servicing
Zero clearance is permissible to either side of the Mini
SMART, but information labels may be hidden.
Reference the boiler installation manual for minimum
allowable clearances of the boiler.
APPLICATION TYPES
The Mini Smart is provided with a NTC (IDWH) sensor
compatible with Honeywell’s MCBA control module. This
control is utilized on Triangle Tube’s PRESTIGE Solo
Wall Hung Condensing Boilers and is featured in these
instructions on pages 8-16. This sensor is also compati-
ble with other boilers equipped with Honeywell’s MCBA
control or with an optional aquastat see page 18.
NOTICE
CODE COMPLIANCE
This product must be installed in accordance with the
instructions in this manual and where applicable:
-
With all local, state, provincial and national
codes, laws, regulations and ordinances
Where recommendations in this manual differ from local
or national codes, the local or national codes take prece-
dence.
CODE RESTRICTIONS
The Mini SMART contains a single wall heat exchanger
and complies with National Standard Plumbing Code
provided both:
-
Boiler water (including additives) is practically
non-toxic having a toxicity rating or a Class of 1
as listed in Clinical Toxicology of Commercial
Products, and
-
Boiler water pressure is limited to maximum 30
psig by approved relief valve.
Single wall heat exchangers are permitted under
Uniform Plumbing Code – Paragraphs L3.2 and L3.3 if
they satisfy all of the following requirements:
1. The heat transfer medium is potable water or con-
tains only substances, which are recognized as safe
by the US Food and Drug Administration.
2. The pressure of the heat transfer medium is main-
tained less than the normal minimum operating
pressure of the potable water system.
3. The equipment is permanently labeled to indicate
that only additives recognized as safe by the FDA
shall be used in the heat transfer medium.
Other heat exchangers designs may be permitted where
approved by the administrative authority.
OPERATING RESTRICTIONS
Maximum Domestic Hot Water Temperature - 180°F
(special applications)
Maximum Boiler Water Temperature - 200°F
Maximum Domestic Operating Pressure – 150 psi
Maximum Boiler Operating Pressure – 30 psi