background image

11

Tools Required
You will need a #2 Phillips screwdriver.

Installing the PCO CELL:
1.  Position  the  PCO Cell inside the unit so that the 

two  tabs  are  on  the  bottom  (and  interior  side)  of 
the  PCO Cell.  Ensure  the  holes  in  the  two  tabs 
fit  over  the  two  Screw Posts.    Screw  the  Thumb 
Nuts
 onto the Screw Posts until they are snug. 

2.  Align the PCO Cell Power Connector to the PCO Cell 

Power Connector Outlet and insert gently until the 
tabs  at  the  top  and  bottom  of  the  PCO Cell Power 
Connector
 snap into place, holding it in the PCO Cell 
Power Connector Outlet
.

Installing the PURIFICATION PLATE:
Holding  the  Purification  Plate  by  the  ceramic,  slowly 
insert it into the Purification Plate Slot, ensuring that the 
Purification Plate is sliding into the grooves on either side. 

NOTE: About halfway in, the Purification Plate Connectors 
are parted. Continue sliding the Purification Plate into the 
Purification Plate Slot until there is approximately one inch 
of the Purification Plate remaining outside of the Purification 
Plate Slot
  and significant resistance is met. Be careful not 
to force the Purification Plate further into the Purification 
Plate Slot
 as this could seriously damage your unit.

Installing the FILTER ASSEMBLY:
1.  Hold  the  Filter Assembly  with  the  larger  flat  side 

facing  the  interior  of  the  unit.  A  sticker  reading, 
“Caution: Reinstall Filter After Cleaning,” is located on 
the opposite side of the Filter Assembly. This sticker 
should be visible when you install the Filter Assembly
 

2.  Insert  the  bottom  of  the  Filter Assembly into 

the  tabs  on  the  rear  of  the  unit  and  then  seat  the 
Filter Assembly  on  the  rear  of  the  unit.  (NOTE: 
If  the  user  fails  to  insert  the  Filter Assembly 
into  the  tabs  appropriately,  disassembling  the 
unit  in  the  future  could  be  extremely  difficult.) 

3.  Screw the two Brass Thumbscrews into their holes at the 

top corners of the Filter Assembly.

Installing the Rear Cover:
1.  Place the tab at the top of the Rear Cover into the hole 

at the top of the Filter Assembly then lay the Rear 
Cover 
flat against the rear of the unit until the tabs on 
the sides of the Rear Cover click into place on the unit. 

2.  Carefully insert the Rear Cover Screw into its hole 

on the Rear Cover  (above  the  Power Cord Port)  
and tighten.

Installing the POWER CORD:
1.  Insert the Power Adapter Plug into the rear of the unit. 

2.  Ensure the Power Cord is properly connected to the 

Power Adapter

3.  Insert the Power Plug into a wall outlet.

Turning the unit on:
Press the power button.

Ensure  that  the  unit’s  settings  are  adjusted  to  suit  the  
environment (see “Operations” on page 9).

Assembly

Summary of Contents for air purifier system

Page 1: ...Manual Welcome Records 2 Specifications Warnings 3 Product Introduction 4 Three Technologies 5 Diagrams 6 7 Setup 8 Operations 9 Dissassembly Assembly 10 11 Cleaning 12 Troubleshooting 13 Table of Co...

Page 2: ...ears of trouble free service when it is properly maintained Keep this manual It will guide you through the steps to operate your machine and the maintenance procedures which will keep your Triad Aer i...

Page 3: ...or cleaning of your unit Warnings Specifications WARNING Never operate unit near heat source open flame or flammable combustible fluids WARNING Do not operate unit unless all parts including PCO Cell...

Page 4: ...quality of air but most importantly it will improve the quality of life Ease of Use The Triad Aer is your hassle free provider for clean air and healthy living With proper care and maintenance see CLE...

Page 5: ...rs that can only filter out particles of 5 microns or larger the ionizer in the Triad Aer can reduce ultra fine even nano particles that are much more dangerous than the larger particles you can actua...

Page 6: ...edle Front Grille Control Panel Rear Cover Screw Rear Cover Clasps Power Adapter Inlet Rear Cover Unit Rear Unit Front 2 Diagrams Unit Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Remo...

Page 7: ...TING MUST NOT EXCEED SIZE OF AREA NORMAL AWAY PERFORM CLEANING REPLACE PCO CELL REPLACE PLATE AREA MUST BE UNOCCUPIED 1 1 7 7 4 4 2 2 5 5 3 3 3 6 6 Fan Speed Indicator Mode Indicator Purification Leve...

Page 8: ...ou have a 2500 square foot house The living room is attached to the kitchen three bedrooms the den and a laundry room The kitchen and three bedrooms doors remain open the majority of the time but the...

Page 9: ...ormal Mode Operations LCD Reminders Replace Plate When ReplacePlate appears thePurificationPlatehas reached the end of its useful life and must be replaced To order a replacement contact your distribu...

Page 10: ...Cover aside Removing the Filter Assembly 1 Remove Brass Thumbscrews from the top corners of the Filter Assembly Place Brass Thumbscrews where you will find them easily during reassembly 2 Grasp the to...

Page 11: ...ling the FILTER ASSEMBLY 1 Hold the Filter Assembly with the larger flat side facing the interior of the unit A sticker reading Caution Reinstall Filter After Cleaning is located on the opposite side...

Page 12: ...he PCO Cell Cleaning the Purification Plate Using a 50 50 mix of warm water and clear ammonia 100 white vinegar can be used in place of water and ammonia soak the Purification Plate for 8 10 hours but...

Page 13: ...cal Arc an Arcing Noise or a Burning Odor 1 This means the Purification Plate is damaged and must be replaced The unit may or may not display the Replace Plate LCD reminder To order a replacement cont...

Page 14: ...14 Triad Aer 2012 All Rights Reserved Notes...

Page 15: ...15 Notes...

Page 16: ...Copyright Triad Aer Triad Aer OM v1 120118...

Reviews: