5

    

 

   Filtration 

The washable pleated filter inside the Triad Aer is an essential component of the three purification technologies.  The 
washable pleated filter passively removes a wide range of particles from the breathing space and holds them until the 
unit is cleaned.  Besides removing particles from the air, the washable pleated filter also prevents them from being 
deposited inside the machine which helps your Triad Aer last longer and perform at optimum efficiency.
 

 

   Needlepoint Ionization 

The Triad Aer generates a continuous stream of millions of negative ions that circulate throughout the home. These ions 
charge particles (such as dust, dander or bacteria) causing them to attract other particles and clump together. As more 
and more particles come together, they become heavier, making them easier to pull into the home’s HVAC air filter or 
just fall to the floor to be vacuumed up. Unlike HEPA filters that can only filter out particles of .5 microns or larger, 
the ionizer in the Triad Aer can reduce ultra-fine, even nano particles, that are much more dangerous than the larger 
particles you can actually see.  

 

  Advanced Photo Catalytic & Scalable Oxidation 

Both the Advanced Photo Catalytic Oxidation (PCO) and Scalable Oxidation work to destroy biological contaminates 
as well as odors, mold, bacteria and viruses. PCO Cells have been proven to reduce dangerous pathogens by more than 
99% in less than 24 hours through a process called molecular disassociation which actually breaks down the molecules 
instead  of  simply  covering  up  the  source.  Scalable  Oxidation  ensures  your  Triad  Aer  will  perform  at  the  maximum 
efficiency specific to its environment at the time of use. In High Mode, the purification plate generates activated oxygen 
to assist in breaking down contaminates which cause odors. For faster cleanup, Triad Aer can be set to Sani+Booster 
which has a programmable auto-shutoff timer feature. This allows the machine to generate maximum output when the 
room or home is unoccupied. 

Three Technologies

Summary of Contents for air purifier system

Page 1: ...Manual Welcome Records 2 Specifications Warnings 3 Product Introduction 4 Three Technologies 5 Diagrams 6 7 Setup 8 Operations 9 Dissassembly Assembly 10 11 Cleaning 12 Troubleshooting 13 Table of Co...

Page 2: ...ears of trouble free service when it is properly maintained Keep this manual It will guide you through the steps to operate your machine and the maintenance procedures which will keep your Triad Aer i...

Page 3: ...or cleaning of your unit Warnings Specifications WARNING Never operate unit near heat source open flame or flammable combustible fluids WARNING Do not operate unit unless all parts including PCO Cell...

Page 4: ...quality of air but most importantly it will improve the quality of life Ease of Use The Triad Aer is your hassle free provider for clean air and healthy living With proper care and maintenance see CLE...

Page 5: ...rs that can only filter out particles of 5 microns or larger the ionizer in the Triad Aer can reduce ultra fine even nano particles that are much more dangerous than the larger particles you can actua...

Page 6: ...edle Front Grille Control Panel Rear Cover Screw Rear Cover Clasps Power Adapter Inlet Rear Cover Unit Rear Unit Front 2 Diagrams Unit Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Remo...

Page 7: ...TING MUST NOT EXCEED SIZE OF AREA NORMAL AWAY PERFORM CLEANING REPLACE PCO CELL REPLACE PLATE AREA MUST BE UNOCCUPIED 1 1 7 7 4 4 2 2 5 5 3 3 3 6 6 Fan Speed Indicator Mode Indicator Purification Leve...

Page 8: ...ou have a 2500 square foot house The living room is attached to the kitchen three bedrooms the den and a laundry room The kitchen and three bedrooms doors remain open the majority of the time but the...

Page 9: ...ormal Mode Operations LCD Reminders Replace Plate When ReplacePlate appears thePurificationPlatehas reached the end of its useful life and must be replaced To order a replacement contact your distribu...

Page 10: ...Cover aside Removing the Filter Assembly 1 Remove Brass Thumbscrews from the top corners of the Filter Assembly Place Brass Thumbscrews where you will find them easily during reassembly 2 Grasp the to...

Page 11: ...ling the FILTER ASSEMBLY 1 Hold the Filter Assembly with the larger flat side facing the interior of the unit A sticker reading Caution Reinstall Filter After Cleaning is located on the opposite side...

Page 12: ...he PCO Cell Cleaning the Purification Plate Using a 50 50 mix of warm water and clear ammonia 100 white vinegar can be used in place of water and ammonia soak the Purification Plate for 8 10 hours but...

Page 13: ...cal Arc an Arcing Noise or a Burning Odor 1 This means the Purification Plate is damaged and must be replaced The unit may or may not display the Replace Plate LCD reminder To order a replacement cont...

Page 14: ...14 Triad Aer 2012 All Rights Reserved Notes...

Page 15: ...15 Notes...

Page 16: ...Copyright Triad Aer Triad Aer OM v1 120118...