background image

9

Operating the Unit

Turning the Unit On/Off
Press the Power Button on the Control Panel or Remote 
to  turn  the  unit  on.  The  unit  will  initially  be  set  to 
Normal Mode.  Press  the  Power Button once more to 
turn the power off.

Using Normal Mode 
Press Normal/High button until “Normal” is shown in 
the lower right of the Display.

•  Square  Footage  not  available  in  “Normal”  

(see “INITIAL SETUP: Initial Settings” page 8).

•  To control the fan speed: Use Fan Up/Down buttons.

Using High Mode
Press the Normal/High button and verify that “High” is 
shown in the lower right of the Display

•  To set the square footage on the Display: 
•  Use Purifier Up/Down
 buttons (see INITIAL SETUP: 

Initial Settings” page 8).

•  To control the fan speed: Use Fan Up/Down buttons.

CAUTION: 

Never  adjust  setting  to  exceed  square  

footage of ventilated space being treated.

Using Sani+Booster
Press the Sani+Booster button and verify that “Away” 
is shown in the lower right of the Display. 

•  To set the Sani+Booster Timer: press the Sani+Booster  

button.  Each  press  of  the  Sani+Booster  button 
increases the running time of the Sani+Booster.

•  Select 

0:30, 

1:00, 

or 

2:00 

hours. 

Press  Sani+Booster once more to switch the 
unit back to Normal Mode.

Operations

LCD Reminders

Replace Plate
When “Replace Plate” appears, the Purification Plate has 
reached the end of its useful life and must be replaced. 
To order a replacement, contact your distributor.  Once 
a replacement has been obtained, follow the instructions 
in “DISASSEMBLY/ASSEMBLY”  (pages  10-11)  to 
replace your old Purification Plate with your new one.

Replace PCO Cell
When “Replace  PCO Cell”  appears,  the  PCO Cell 
has reached the end of its useful life and must 
be  replaced.  Contact  your  distributor  to  order  a 
replacement.  Once  a  replacement  has  been  obtained, 
follow the instructions in “DISASSEMBLY/
ASSEMBLY
”  (pages  10-11)  to  replace  your  old  
PCO Cell with your new one. 

Perform Cleaning
Perform Cleaning”  will  display  once  the  30  day 
operation cycle between cleanings has passed and the unit 
requires a complete cleaning. Follow the instructions in  
CLEANING” (page 12) then see “Resetting Reminders” 
(below) to reset the reminders. The Perform Cleaning 
reminder will appear again after 30 day of operation.

Resetting Reminders
After  replacing  the  Purification  Plate or the PCO Cell
the corresponding reminders will reset themselves. After 
performing a cleaning of the unit (see “CLEANING” page 
12) you should reset the reminders by holding down the 
Reminder Reset button on the Control Panel of the unit. 
The reminder has been reset when Perform Cleaning no 
longer appears. 

Summary of Contents for air purifier system

Page 1: ...Manual Welcome Records 2 Specifications Warnings 3 Product Introduction 4 Three Technologies 5 Diagrams 6 7 Setup 8 Operations 9 Dissassembly Assembly 10 11 Cleaning 12 Troubleshooting 13 Table of Co...

Page 2: ...ears of trouble free service when it is properly maintained Keep this manual It will guide you through the steps to operate your machine and the maintenance procedures which will keep your Triad Aer i...

Page 3: ...or cleaning of your unit Warnings Specifications WARNING Never operate unit near heat source open flame or flammable combustible fluids WARNING Do not operate unit unless all parts including PCO Cell...

Page 4: ...quality of air but most importantly it will improve the quality of life Ease of Use The Triad Aer is your hassle free provider for clean air and healthy living With proper care and maintenance see CLE...

Page 5: ...rs that can only filter out particles of 5 microns or larger the ionizer in the Triad Aer can reduce ultra fine even nano particles that are much more dangerous than the larger particles you can actua...

Page 6: ...edle Front Grille Control Panel Rear Cover Screw Rear Cover Clasps Power Adapter Inlet Rear Cover Unit Rear Unit Front 2 Diagrams Unit Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Remo...

Page 7: ...TING MUST NOT EXCEED SIZE OF AREA NORMAL AWAY PERFORM CLEANING REPLACE PCO CELL REPLACE PLATE AREA MUST BE UNOCCUPIED 1 1 7 7 4 4 2 2 5 5 3 3 3 6 6 Fan Speed Indicator Mode Indicator Purification Leve...

Page 8: ...ou have a 2500 square foot house The living room is attached to the kitchen three bedrooms the den and a laundry room The kitchen and three bedrooms doors remain open the majority of the time but the...

Page 9: ...ormal Mode Operations LCD Reminders Replace Plate When ReplacePlate appears thePurificationPlatehas reached the end of its useful life and must be replaced To order a replacement contact your distribu...

Page 10: ...Cover aside Removing the Filter Assembly 1 Remove Brass Thumbscrews from the top corners of the Filter Assembly Place Brass Thumbscrews where you will find them easily during reassembly 2 Grasp the to...

Page 11: ...ling the FILTER ASSEMBLY 1 Hold the Filter Assembly with the larger flat side facing the interior of the unit A sticker reading Caution Reinstall Filter After Cleaning is located on the opposite side...

Page 12: ...he PCO Cell Cleaning the Purification Plate Using a 50 50 mix of warm water and clear ammonia 100 white vinegar can be used in place of water and ammonia soak the Purification Plate for 8 10 hours but...

Page 13: ...cal Arc an Arcing Noise or a Burning Odor 1 This means the Purification Plate is damaged and must be replaced The unit may or may not display the Replace Plate LCD reminder To order a replacement cont...

Page 14: ...14 Triad Aer 2012 All Rights Reserved Notes...

Page 15: ...15 Notes...

Page 16: ...Copyright Triad Aer Triad Aer OM v1 120118...