STEP ‘F’ - ADJUST ID CHAMBER BIT
1. Before any adjustment can
be made, all hex screws
must be loosened, and the
inside cup brush must be
loosened.
2. Bring headstock close to the
test bevel.
3. Leave a gap between
the bevel bit and bevel of
the same amount as the
desired camfer
dimension.
Do not
crash tool bits into
the bevel or damage
will occur.
4. Rotate the axial
adjustment screw
and advance the
chamfer tool holder
until it touches the
edge of the pipe.
Do not force it.
5. Retract headstock all the
way back.
6. Tighten all hex screws and
reset and tighten the cup
brush.