- 17 -
MAINTENANCE
2.
Remove impeller.
3.
Remove casing (1) by removing nuts (13) and washers (14).
4.
Torque hex head screws (37) securing the compression ring and threaded compression ring to
132 lb-in or 11 lb-ft (15 Nm). Note that hex head screws are metric (wrench size is 10mm).
ROTATING SEALS AND PUMP CASING ASSEMBLY
Type DG - External Balanced Seal
1.
If assembling DG type seals, install o-ring (5) into rotating seal (15). Then assemble the rotating
seal (15) and spring (16) onto the drive collar (17).
For the CL4311 or CL6410 pump, insert the pin (19) into the drive collar, and install the o-ring
(5) into the rotating seal (15). Then assemble the rotating seal (15) and spring (16) onto the
drive collar (18).
2.
Place the assembled seal on the stub shaft. The drive collar notch must align with the pin on the
stub shaft.
Ensure the drive collar pin enters the notch on the rotating seal cup when the spring is
compressed.
Drive Collar Pin
Notch in Cup
Torque 6 compression ring screws to 132 lb-in or 11 lb-ft
(15Nm). Screws are metric. Wrench size is 10mm.