![Tri-Clover Tri-Flo CL Series Service & Installation Manual Download Page 10](http://html.mh-extra.com/html/tri-clover/tri-flo-cl-series/tri-flo-cl-series_service-and-installation-manual_1159609010.webp)
- 10 -
MAINTENANCE
REMOVING PUMP PARTS
DISASSEMBLY
1.
Remove seal guard (32) by removing screw (33).
2.
Remove wingnuts (6) securing cover (3) to casing (1).
3.
Remove front cover (3). Use the two slots in casing (1) and a screwdriver to pry cover off.
4.
Remove impeller screw (4) from stub shaft.
5.
Unscrew impeller (2) from stub shaft.
6.
Remove o-ring (5) on impeller (2) and o-ring (8) on cover as required.
8
3
6
Slot
Relieve pressure and
remove all fluid from pump
prior to disassembly.
4
5
2
1
32
33
WARNING
High voltage. Only an
authorized electrician
should disconnect the
pump.