![Tri-Clover Tri-Flo CL Series Service & Installation Manual Download Page 11](http://html.mh-extra.com/html/tri-clover/tri-flo-cl-series/tri-flo-cl-series_service-and-installation-manual_1159609011.webp)
- 11 -
MAINTENANCE
If disassembling pump with stuffing box and flushing pipes, remove as follows:
1.
Remove flushing pipes (24) from stuffing box (22 or 28).
2.
Remove casing (1) by removing nuts (13) and washers (14).
3.
Remove stuffing box (22 or 28) from casing by removing two screws (23) securing stuffing
box to casing.
STATIONARY SEAL DISASSEMBLY
Disassemble casing as follows:
1.
Remove seal gland (10) on back of casing by removing allen screws (9) and washers (38).
2.
Remove rear gasket (11), stationary seal (12), and front gasket (11) as required. NOTE: A
rear elastomer gasket is required when using a front PTFE gasket.
13
14
1
23
24
22, 28
10
11
12
11
9
1
38