![Tri-Clover Tri-Flo CL Series Service & Installation Manual Download Page 14](http://html.mh-extra.com/html/tri-clover/tri-flo-cl-series/tri-flo-cl-series_service-and-installation-manual_1159609014.webp)
- 14 -
PUMP PARTS DISASSEMBLY
After the seals are removed and disassembled, remove the following:
1.
Remove pump adapter (29) from motor by removing hex head cap screws (30) and washers
(31).
2.
Remove compression ring (36), threaded compression ring (35) and retaining ring (40) (used
on 1.5 HP and 2 HP motors only) by removing screws (37) and washers (38). Note that hex
head screws are metric (wrench size is 10mm).
3.
Remove pin (39) from stub shaft (34) as required.
4.
Remove stub shaft from motor shaft as required.
1.
Remove leg brackets (41) from motor (46) by removing hex head cap screws (42) and
washers (43).
2.
Remove adjustable legs (45) from leg brackets (41) by removing set screws (44).
MAINTENANCE
30
31
39
34
Screws are metric.
Wrench size is 10mm.
29
38
37
36
40
46
42
43
45
41
44
35