63 of 63
EMC
Test Report: CE03111004-A
28. Voltage Dips and Voltage Interruptions Immunity Tests
Final Test Result
:
PASS
Pass
performance Criteria
TT/TR for voltage interruption, CT/CR and TT/TR for voltage dips
Required performance criteria
TT/TR for voltage interruption, TT/TR for voltage
dips
Basic Standard
:
EN 61000-4-11:1994/A4:2000
Product Standard
EN 301 489-17
Temperature :
25
°
C
Relative Humidity
:
50 %
Test Date
:
Nov. 28, 2003
28.1.
TEST LEVEL
TEST RECORD OF VOLTAGE INTERRUPTION/ DIPS
Test mod
Voltage
dips
Durations
(period / ms)
Interval(s)
Times Phase Result
Voltage interruptions
100% 5000 10 12
0
°
/180
°
B
60% 100 10
12
0
°
/180
°
N
Voltage dips in %U
T
30% 10 10
12
0
°
/180
°
N
Note: “N” means the EUT function was correct during test.
“B” means the EUT’s function was fail during the test, the EUT operate as
intended without operator intervention.
EMS Test Engineer: Kevin Lee