E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
49 of 49
EMC
Test Report: CE03111004-A
22. Voltage Fluctuations Test
z
Basic Standard : EN 61000-3-3:1995/A1:1998
z
FINAL TEST RESULT :
PASS
z
Temperature :
25
℃
z
Test Data : Nov. 28, 2003
z
Relative Humidity
: 50 % RH
Pst
Plt
Dc ( % )
Dmax ( % )
Dt ( % )
Reading 0.070 0.070 0.00
0.00
0.00
Limit
0.65 1.0 3.0 4.0 3.0
22.1.
TEST EQUIPMENT SETTINGS
z
Line Voltage : 230 V
z
Test Duration : 00:10:00 minutes
z
Line Frequency : 50 Hz
z
Measurement Delay : 10.0 seconds
z
Pst Integration Periods : 1
z
Pst Integration Time : 10 minutes