E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
32 of 32
EMC
Test Report: CE03111004-A
19.1.2 Test Mode 3 (CH 13b@ 11Mbps Bit-Rate)
Relative Humidity: 70 %
Temperature: 24
°
C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■
The test was passed at the minimum margin that marked under gray area in the following table
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.373
46
53.3
---
22.6
0.3
46.3 53.6
---
22.9 58.4
48.4
-4.9
-25.6
0.539
38.2 45.2
---
21.8
0.3
38.5 45.5
---
22.1 56.0
46.0
-10.5
-23.9
0.609
35.5 47.5
---
17.7
0.3
35.8 47.8
---
18
56.0
46.0
-8.2
-28
0.789
29.9 42.9
---
21.3
0.3
30.2 43.2
---
21.6 56.0
46.0
-12.8
-24.4
1.004
31.4 34.7
---
11.7
0.3
31.7
35
---
12
56.0
46.0
-21.0
-34
1.07
32.1 33.4
---
10.9
0.3
32.4 33.7
---
11.2 56.0
46.0
-22.3
-34.8
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Factor
Result (dBuV)
Q.P Value AVG. Value
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.