E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
6 of 6
EMC
Test Report: CE03111004-A
2. Test Distance
a. The test distance of radiated emission test from antenna to EUT is 10 M.
b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M.
2.1.
Summary of Test Results
19.1.1 Emission Tests
Measurement Reference
Clause(s)
Test
Reference standard
Radiated emission
8.2
PASSED
EN 55022/A1:2000 class B
Conducted emission
8.3/8.4
PASSED
EN 55022/A1:2000 class B
Harmonic current
emissions
8.5
N/A
EN 61000-3-2:2000
Voltage fluctuations
and flicker
8.6
PASSED
EN 61000-3-3:1995
19.1.2 Immunity Tests
Measurement Reference
Clause(s)
Test
Reference standard
Electrostatic
discharge
9.3
PASSED EN
61000-4-2:1995/A1:1998
RF electro-magnetic
Field (80-1000 MHz,
1400-2000 MHz.)
9.2
PASSED EN
61000-4-3:1996/A1:1998
Fast transients
common mode
9.4
PASSED
EN 61000-4-4:1995
Surge 9.8
PASSED
EN 61000-4-5:1995
Radio frequency,
common mode
9.5
PASSED
EN 61000-4-6:1996
Voltage dips and
interrupts
9.7
PASSED
EN 61000-4-11:1994