© Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
TFC‐1600MM
12
Configure your Module (Command Line Interface)
Console and Terminal Emulator program settings
The Media Converter Chassis Management Module can be accessible using a terminal or terminal emulator attached to the RJ‐45 UTP console port.
Serial port configuration cable:
One end of the cable is a DB9 serial port, which connects to serial port on computer. Other end is an RJ‐45 UTP port, which connects to the SNMP Media Converter Chassis.
To configure the Hyper Terminal of the management PC via serial port configuration cable to manage the Media Converter Chassis.
By default, the Media Converter Management Module uses the following serial port parameter values:
Bits per second
115200
Stop bits
1
Data bits
8
Parity
NONE
Flow Control
NONE
The default Login name and password is both “
root
”.
TELNET program setting
The Media Converter Chassis Management Module can be accessible using TELNET through LAN. Run TELNET program. Enter the IP address “
192.168.1.1
” (the factory‐default IP address
setting). The default Login name and password is both “
root
”.
The Command Line Interface (CLI) has following functions:
Reboot
Factory Reset
Image Update
General Configuration
IP interface configuration
SNMP Configuration
CPU module information
Media Converter Configuration
Redundant Backup Setting
Configuration