Connections
9
Figure 5: Connecting an output VIO contact for handling the load voltage of greater than 12V
3.4
Connecting a Radio
You can connect Swift DT500 to a MOTOTRBO digital two-way mobile radio for IP or
non-IP communication.
Non-IP communication with a peripheral device requires preliminary setup on the
radio.
To setup the radio for non-IP communication with a peripheral device:
1.
Disconnect peripherals from the radio.
2.
Connect the radio to a computer and run the MOTOTRBO CPS software.
3.
Read the radio settings.
4.
Go to the
Accessories
section and set
Cable Type
to
Rear Data Accessory
.
5.
Write the new settings to the radio.
Note: If the radio has a display and changing the cable type through the radio menu
is allowed, you can make the same changes without using the MOTOTRBO CPS
software.
To connect Swift DT500 to a MOTOTRBO radio:
1.
Power off the radio.
2.
Connect Swift DT500 to external hardware (if required).
3.
Use the service cable by Neocom Software, Ltd to connect the radio port of
your Swift DT500 to the service port of the radio. The service cable is supplied
with Swift DT500 in the delivery kit.
Figure 6: Pinout diagram of the radio cable for non-IP communication