3. Be sure not to compress the IN/OUT cables.
NOTE: To keep LED pitch consistent and allow for thermal expansion, be sure to keep a minimum distance of
2mm (0.08”) between consecutive Media Tube® Go (see below diagram).
FIG.8: Keep minimum distance between fixtures
To maintain consistent LED pitch and to allow for thermal expansion, a minimum of
2mm / 0.08" is required between luminaire's.
End Cap Seal on Last Tube
≥2mm / 0.08"
4. The first tube of the daisy-chain group has to be connected to the control system via Waterproof Junction
Box (by others).Starter cables, Data and Power cables, and video fiber optic cables have to be installed
through conduit.
5. Set up the control system indoors as detailed in the System Diagram and connect to the Media Tube
®
Go.
Start each unit and verify correct function.
NOTE: For manual addressing setups, please refer to the configuration guide of TX Smart Addresser