![Travis Industries Xtrordinair 44 Elite Manual Download Page 46](http://html.mh-extra.com/html/travis-industries/xtrordinair-44-elite/xtrordinair-44-elite_manual_1154150046.webp)
OMNI-Test Laboratories, Inc.
Run:
3
Travis Industries
PM Control Modules:
371, 372
44 Elite
Dilution Tunnel MW(dry):
29.00 lb/lb-mole
Avg. Tunnel Velocity:
#DIV/0!
ft/sec.
2305
142
min
Dilution Tunnel MW(wet):
28.78 lb/lb-mole
Initial Tunnel Flow:
#DIV/0!
scfm
Technician Signature:________________________________
0028WF061E
Recording Interval:
2
min
Dilution Tunnel H2O:
2.00 percent
Average Tunnel Flow:
#DIV/0!
scfm
12-Sep-18
Dilution Tunnel Static:
"H2O
Post-Test Leak Check (1):
cfm @
in. Hg
Beginning Clock Time:
Background Sample Volume:
cubic feet
Tunnel Area:
0.19635
ft2
Post-Test Leak Check (2):
cfm @
in. Hg
Pitot Tube Cp:
0.99
Average Test Piece Fuel Moisture:
21.97
Dry Basis %
Meter Box Y Factor:
0.983
(1)
0.974
(2)
(Amb)
Barometric Pressure:
Begin
Middle
End
Average
Pt.1
Pt.2
Pt.3
Pt.4
Pt.5
Pt.6
Pt.7
Pt.8
Center
29.42
29.37
29.40 0
Initial dP
"H2O
OMNI Equipment Numbers:
Temp:
°F
V
strav
ft/sec
V
scent
ft/sec
F
p
Particulate Sampling Data
Elapsed
Time (min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter 1
Temp
(°F)
Meter 1
Vacuum
("Hg)
Orifice
dH 2
("H
2
O)
Meter 2
Temp (°F)
Meter 2
Vacuum
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center dP
Pro. Rate
1
Pro. Rate
2
Scale
Reading
Weight
Change
Firebox Top
Firebox
Bottom
Firebox
Back
Firebox Left
Firebox
Right
Avg. Stove
Surface
Catalyst
Stack
Filter 1
Dryer
Exit 1
Filter 2
Dryer
Exit 2
Ambient
Draft
("H
2
O)
CO
2
(%)
CO
(%)
Wood Heater Test Data
Efficiency Data
Test Date:
Stack Gas Data
Fuel Weight (lb)
Temperature Data (°F)
Velocity Traverse Data
Manufacturer:
Model:
Tracking No.:
Total Sampling Time:
Project No.:
Export to
140
4.7
384
85
357
185
148
232
895
637
82
142
4.4
388
85
362
186
149
234
890
627
81
Avg/Tot
0.000
0.000
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
62.2
#DIV/0!
#DIV/0!
#DIV/0!
76
#DIV/0!
Control No. P-SSAR-0003
Page 5 of 8
Run 3 Burn Rate test data
46 of 158
Summary of Contents for Xtrordinair 44 Elite
Page 36: ...36 of 158 ...
Page 37: ...37 of 158 ...
Page 49: ...49 of 158 ...
Page 59: ...59 of 158 ...
Page 60: ...60 of 158 ...
Page 69: ...69 of 158 ...
Page 70: ...70 of 158 ...
Page 84: ...84 of 158 ...
Page 85: ...85 of 158 ...
Page 89: ...89 of 158 ...
Page 90: ...90 of 158 ...
Page 91: ...91 of 158 ...
Page 92: ...92 of 158 ...
Page 93: ...93 of 158 ...
Page 94: ...94 of 158 ...
Page 95: ...95 of 158 ...
Page 96: ...96 of 158 ...
Page 97: ...97 of 158 ...
Page 98: ...98 of 158 ...
Page 99: ...99 of 158 ...
Page 101: ...101 of 158 ...
Page 102: ...102 of 158 ...
Page 103: ...103 of 158 ...
Page 104: ...104 of 158 ...
Page 106: ...7 20 18 106 of 158 ...
Page 109: ...7 20 18 109 of 158 ...
Page 111: ...111 of 158 ...
Page 112: ...112 of 158 ...
Page 113: ...113 of 158 ...
Page 115: ...115 of 158 ...
Page 130: ...130 of 158 ...
Page 151: ...Safety Label 21 Travis Industries 10 24 2018 93508094 44 Elite Owner s 151 of 158 ...