20 Installation
(for qualified installers only)
© Travis Industries
10/16/17 - 1453
PB 42 MV/GSB2 Install
5
On the header shield, bend the two tabs downward approximately 90 degrees. Set the header shield
onto the standoffs with the 90
°
bend facing the pipe shield. The tips of the standoffs will protrude through
the heat shield. Attach the heat shield to the standoffs by aligning the holes on the heat shield tabs with
the holes in the header standoffs and secure using the included screws
6
When finished the fireplace should be configured like the picture below.
Bend tabs
down 90
°
Align holes