Installation
(for qualified installers only)
37
© Travis Industries
10/16/17 - 1453
PB 42 MV/GSB2 Install
Standard vs. Extended Position
The nailing brackets on the side of the fireplace may be placed in the standard or extended position to best suit
the facing being used (the header shield is also moved). Most installations use the standard nailing bracket
position. If using a facing that does not use a backing board (e.g. marble), you may wish to use the extended
position.
Facing Thicker than 1-1/2” (not recommended)
The screen assembly may be positioned 1/2” to 1-1/2” from the front of the fireplace to allow facing to tuck under
the screen assembly.
Facing thicker than 1-1/2” is not recommeneded.
If using facing greater than 1-1/2”is used, make sure to leave a 1/2" gap above the screen assembly and 1/8” to
the sides and below. This gap is required to allow for the screen assembly to be removed.
Standard Position - Top View
(nailing brackets as shown to right)
Optional Tile
(or other non-combustible)
Drywall
Cement Board
(or other non-combustible)
Nailing Bracket
Fireplace
Framing
Non-Combustible Facing
(marble, etc.)
Drywall
Nailing Bracket
Fireplace
Framing
Extended Position - Top View
(nailing brackets as shown to right)
Nailing Bracket
Nailing Bracket