Safety
Label
41
© Travis Industries
4120301
100-01286_000
Safety Label
The safety (listing) label is attached to the operating tag (chained to the heater near the gas control
valve). A copy is shown below
Report No. B051
1PRT
-001
Control No. 4000515
Tested to:
ANSI Z21.88-2009/CSA
2.33-2009 “V
ented Gas Fireplace Heater”, CGA
2.17-M91 (R2009) “Gas Burning
Heating
Appliances for Manufactured Homes”, and CSA
P
.4.1-09 T
esting method for measuring annual fireplace
efficiency
.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas
Code,
ANSI Z223.1/NFP
A
54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA
Z240 MH, Mobile Housing,
in Canada or with the Manufactured Home Constructions and Safety Standard, T
itle 24 CFR, Part 3280, in the
United States, or when
such a standard is not applicable,
ANSI/NCSBCS
A225.1/NFP
A
501A, Manufactured Home
Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP)
is desired, the optional factory conversion kit must be used. DVS GSR Insert: Part No. 94400999 register
kit may
be used. 33 DVI Insert: Part No. 250-02378 register kit may be used.
This appliance is only for
use with the type(s) of gas indicated on the rating plate and may be installed in an
aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes. See owner
’s manual for details.
This appliance is not convertible
for use with other gases, unless a
certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying
appliance.
This appliance must be properly
connected
to a venting system in accordance with the manufacturer
’s
installation instructions. Use only approved coaxial direct
vent
system to vent
this appliance
to the
exterior
. See
owner
’s manual for approved brands of venting.
If the
vent-air
intake
system is disconnected for servicing or any other reason, it must be resealed and / or
reinstalled.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the owner
’s information manual provided with this appliance. For assistance or additional
information consult a qualified installer
, service agency or the gas supplier
.
Minimum Clearances to Combustibles
Side of Insert to
Adjacent W
all
Hearth Extension in Front
Hearth Extension to Sides of Insert
4” (102mm)
0” (0mm)
0” (0mm)
Base of Insert to Mantel
Base of Insert to T
op Facing
Flue V
ent
See Owner
’s
Manual
See Owner
’s
Manual
See Owner
’s Manual
Minimum fireplace size with 3 piece panel = Height: 23.75” (604mm), Width:
31.5” (800mm), Depth: 14.5” (369mm), Chimney
height: 8 Feet.
Minimum fireplace size with 1 piece panel = Height: 24.875” (632mm), Width:
32.5” (826mm), Depth: 15.75” (400mm),
Chimney Height: 8 Feet.
FAN TYPE VENTED CIRCULA
T
OR
Blower Electrical Rating: 1
15V
., 1.5
Amps, 60 Hz, 150 W
atts
Part No. 228-10085 / 228-10086 fan or blower assembly may be used
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
L.P
.
11
”
13”
11
”
N.G.
5.5”
7”
3.5”
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
Orifice Size - Front (DMS)
Orifice Size - Rear (DMS)
L.P
.
40,000
7,400
#57
#53
N.G.
40,000
11,900
#49
#43
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See owner
’s
manual for information on making these changes.
W
ARNING: This fireplace
has been converted for use with a gas fireplace
insert only and
cannot be used for
burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the
authority having jurisdiction.
W
ARNING: Failure to install this appliance per the manufacturer
’s
instructions or failure
to use only parts
specifically approved with this appliance may result in property damage or personal injury
.
Manufactured by:
www
.travisproducts.com
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done
by a licensed or qualified service person.