Altitude Considerations
•
This heater has been tested at altitudes ranging from sea level to 2,400 m. In this testing we have found that the
heater, with its standard orifice, burns correctly with just an air shutter adjustment.
•
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Vent Installation
Inlet 76mm (3”)
Exhaust 102mm (4”)
Inlet
Exhaust
Termination Cap
(Simpson Part # 991)
168mm (6-5/8”) to
76mm (3”) & 102mm
(4”) Co-Linear Adapter
(Travis Part #
98900124)
76mm (3”) dia. Gas Liner
102mm (4”) dia. Gas Liner
Use hose-clamps
to secure the vent.
Alternative Method: use high-temperature
silicone and secure with screws.
Use hose-clamps to
secure the vent.
Alternative Method: use
high-temperature
silicone and secure with
screws.