Installation (for authorized personnel only)
© Travis Industries
4040808
100-01201_000
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Side
Wall
Combustible or Non-Combustible Mantel
Combustible Top Facing
Non-Combustible
Facing
Minimum Clearances
k
l
m
n
y
x
Sidewall to Insert
Side Facing
Top Facing*
Mantel*
Hearth Extension
Extension onto Hearth
255mm
102mm
900mm**
1000mm**
305mm
35mm
l
k
x
n
m
* The non-combustible top facing must extend
25mm above the top of the surround panels.
** Measured from the base of the insert.
y
Mantel Clearances
The maximum mantel depth is 305 mm at 1000 mm
vertical height.
** For mantel sizes over 305 mm, the vertical height
must be raised to the equivalent length of the
extended mantel depth as reference from the MIN
value (305 mm).
NOTE
: The combustible area above the facing must
not protrude more than 19 mm from the facing. If it
does, it is considered a mantel and must meet the
mantel requirements listed in this manual.
305 mm
MIN
430 mm
1000 mm
MIN
1130 mm
1260 mm
Vertical Height
Mantel depth