Vent Requirements

 

Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a

factory built type "A" chimney.  All vent joints (including adapters, elbows, etc…) must be sealed with 500°

F. RTV silicone.

 

Pellet vent must maintain a minimum 3" clearance to any combustible (install vent at clearances specified

by the vent manufacturer).

 

Do not connect the pellet vent to a vent serving any other appliance or stove.

 

The maximum venting distance is

shown in the illustration to the right.

 

Do not install a flue damper in the

exhaust venting system of this unit.

 

Use an approved wall thimble when

passing the vent through walls and a

ceiling support/fire stop spacer when

passing the vent through ceilings

(make sure to maintain 3" clearance to

any combustibles.

 

No more than 180° of elbows (two 90°

elbows, one 90° and two 45° elbows,

etc.).

 

Pellet vent connections must be

sealed airtight with 500° F. RTV

silicone and screwed together with at

least three sheet metal screws.

Seal each vent section (including 
adapters, elbows, etc...) by 
injecting a liberal amount of 500° 
F. RTV silicone into the gap 
between sections. 

500

° F. RTV 

Silicone

Vent must have a support bracket

every 5' of pellet vent when exterior of

structure

 

Horizontal sections must have a 1/4"

rise every 12" of travel.

0 Feet

5 Feet

10 Feet (max.)

0 Feet

5 Feet

10 Feet

15 Feet

20 Feet

25 Feet

30 Feet

33 Feet 

(max.)

The vent height and run 

must not exceed the 

distance shown in the 
shaded region shown to the 

right.

NOTE: To achieve optimum 

performance, we 

recommend keeping the 
vent as short as possible 

(horizontal run especially).

Venting into this shaded 

area may require restrictor 

adjustments.  See the 
section “Restrictor 

Adjustment” for details.

Summary of Contents for 99200149

Page 1: ...s is met refer the directions included with the thimble for additional details Remove the starter collar from the pellet heater and install it onto the elbow seal with silicone Determine the correct length for the horizontal section of vent the center of the starter collar is 11 25 behind the enclosure opening and attach it to the elbow seal with silicone Place this flue section aside until after ...

Page 2: ...ough ceilings make sure to maintain 3 clearance to any combustibles No more than 180 of elbows two 90 elbows one 90 and two 45 elbows etc Pellet vent connections must be sealed airtight with 500 F RTV silicone and screwed together with at least three sheet metal screws Seal each vent section including adapters elbows etc by injecting a liberal amount of 500 F RTV silicone into the gap between sect...

Page 3: ...terminations require 24 H G A D F NOTE Measure clearances to the nearest edge of the exhaust hood A E B C F X A Minimum 4 clearance below or beside any door or window that opens B Minimum 1 clearance above any door or window that opens C Minimum 2 clearance from any adjacent building D Minimum 7 clearance above any grade when adjacent to public walkways NOTE Vent may not terminate in covered walkw...

Page 4: ...rround panels are 32 tall When determining depth include the facing material drywall tile etc see the illustration below When venting vertically there is no maximum depth Width Depth Height When determining the position of the insert consider the position of the framing behind the insert relative to the vent see the illustration below When determining the depth include the facing material drywall ...

Page 5: ...ill need to raise the insert and enclosure height the equivalent amount The leveling bolts may be used on the insert for adjustments AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA 45 Min width of surround panels 18 Min Floor Protection AA AA AA AA AAAA...

Page 6: ... top vent applications A A A A Use the included screws to secure the zc can sides and top to the zc can rear panel Rear Vent Shield not required for top vent applications A A A AAA AAA AAA AAA A A A A knock out is provided on the rear panel for rear vent applications Bend the mounting flange as shown AA AA AA AA A A AA AA A A AA AA A AAAAAAA AAAAAAA AAAAAAA Bend the top stand off as shown and secu...

Page 7: ...AAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAA...

Page 8: ...d the use of the Insert Wiring Kit when installing this kit SKU 97200315 This kit allows for the power cord to be hard wired behind the walls eliminating the need for a visible power cord A AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAAAA AA AA AA Wall Thimble note 3 clearance between vent and combustibles 12 Minimum A A A A A A A A A A A A AAAAAAAAAAAAAAA A A A A A A A A A A A Enclosure He...

Reviews: