Appendix 1 - Insights into Pellet Stoves
Page 37
Printed 3/18/98
Travis Industries Pellet Stove Troubleshooting Guide (
1994)
D
ETERMINING WHICH
S
YSTEM IS
F
AULTY
Pellet Feed System
Consists of:
Purpose:
Possible Problems
Hopper
Stores pellets
Debris caught in mouth of auger tube
Auger Motor
Turns the spiraled auger flight
Not correctly attached
Auger Tube
Pushes pellets to feed tube
See the section "Jammed Auger"
Switch Box
Determines the feed rate
Faulty potentiometer (the component next to the
label "BURN RATE") (replace box and check)
Control Box
Turns the auger on and off
Faulty auger timing block (replace box and
check)
Convection Heat System
Consists of:
Purpose:
Possible Problems
Convection Blower
Pushes air into heat exchanger
tubes
Dirty - this component works in conjunction
with the convection snap disk to turn on and off
when the heater is up to temperature.
Heat Exchanger Tubes
Draws the heat off of the fire
If ash is found on inside of these tubes, there may
be an exhaust leak inside the stove - check for an
air-tight seal on the exhaust blower, exhaust
tube, and exhaust vent
Switch Box
Determines the convection blower
speed
Faulty rheostat (the component next to the label
"FAN") (replace box and check)
Electronic Safety System
Consists of:
Purpose:
Possible Problems
Hopper Snap Disk
Turns the heater off for
overheating
Faulty component (replace component and check)
Flow Switch
Turns the heater off for blocked
vent or exhaust blower failure
Faulty component (replace component and check)
I
N ADDITION TO THE ITEMS LISTED ABOVE
,
HEATERS ALSO INCLUDE
THE FOLLOWING
SYSTEMS FOR CONVENIENCE PURPOSES
Start Up and Auto Turn Off Feature
Consists of:
Purpose:
Possible Problems
System Snap Disk
Turns the heater off if the heater
does not reach operating
temperature. This component
also shuts off the exhaust blower
when the heater goes out.
Faulty component (replace component and check)
Auto Ignition Feature
Consists of:
Purpose:
Possible Problems
Igniter
This heating element super-heats
air entering the firepot during
startup, igniting the pellets
Faulty component (replace component and check)
T
HE
5 M
OST
C
OMMON
P
ROBLEMS
¥ Air leaks
¥ Heaters requiring cleaning (especially in manifold and exhaust blower area)
¥ Blocked or Restricted Vent (or installed improperly)
¥ Poor quality pellets
¥ Jammed Auger (pellet jammed in top of auger tube)