VIII. Machine starts to seal before a complete tensioning:
1.
SQ4 (TF-006/T7-1-10750) detect Strap Guide (C) (T5-1-24151) too early. Enlarge their
distance (A) by moving SQ4 to the right slightly or bend Strap Guide (C) to the left a
little as illustrated in the following drawing.
2.
Check if the weld cooling timer or heater temperature adjustment VR pins have contacts
with the control box. Please make sure that they are not in contract with the control box
as illustrated in the following picture.
3.
Replace PC Board (T5-4-10141, T5-4-20501, T5-4-20511, T5-4-10142, T5-4-20502, or
T5-4-20512).
IX.
Straps are not refeeded after machine completes a strapping cycle:
1.
Check if Spring (TC-025/T6-3-10120) is either broken, loosening or worn out.
2.
Straps are stuck around Strap guide assy’ ( T5-1-24001/24002/24005/24007 )or around
Guide (T5-1-20210) so machine is incapable of feeding straps.
3.
Replace PC Board (T5-4-10141, T5-4-20501, T5-4-20511, T5-4-10142, T5-4-20502, or
T5-4-20512).
Weld cooling
timer
Heater temperature
adjustment
The pins can not
touch the control box