Genesis TP-501/TP-502 Q&A
Confidential TO: FROMM HOLDING AG
Page 3 of 8 8/19/2008
You could find this information from our technical training
8.
Replace Heater (T5-1-12320) when Heater Lamp (T5-4-10260) does not light up after
Heater (T5-1-12320) is being warmed up.
9.
Replace PC Board (T5-4-10141, T5-4-20501, T5-4-20511, T5-4-10142, T5-4-20502, or
T5-4-20512).
II.
Machine could not stop at the home position:
1.
Check if Micro Switch SQ2 (TF-006) is installed correctly. When the machine is on
standby, SQ2 should have contacts with Limit Switch Contactor (T5-1-11140) as
illustrated in the drawing.
Please refer to the following instructions for the correct installations:
SQ2/SQ3: SQ2 and SQ3 are fixed together. Please make sure when the SQ2/SQ3 is
activated by the lobes on Limit Switch Contactor (T5-1-11140), the TF-009 (switch trigger)
is not allowed to touch body of SQ2/SQ3.
SQ2
SQ3
Home Position
Cooling
Time
M1: Stop; M2: Reversing
M2: Start