background image

MODELS: EIS-1, EIS-2 OR EIS-4

USER MANUAL

: DOOR ENTRY UNIT

Programming Software

v.02 2018

Summary of Contents for EIS-1

Page 1: ...MODELS EIS 1 EIS 2 OR EIS 4 USER MANUAL DOOR ENTRY UNIT Programming Software v 02 2018...

Page 2: ...ADDING UNITS TO USER PROFILE 12 8 3 WEB SERVER UNIT MANAGEMENT 14 8 4 INTERCOM CONFIGURATION 15 8 5 KEYPAD PIN ENTRY ACCESS 17 8 6 WIEGAND ACCESS 19 8 7 CALLER ID ACCESS 21 8 8 OUTPUTS SETTINGS 22 8 9...

Page 3: ...es with permanent use Error Bookmark not defined Figure 12 WEB Server Adding Wiegand devices with temporary use Error Bookmark not defined Figure 13 WEB Server Caller ID Access 21 Figure 14 WEB Server...

Page 4: ...eters Error Bookmark not defined Table 3 WEB Server Timer setting output mode options 26 Table 4 Wiegand 26 Mode 0 35 Table 5 Wiegand 26 Mode 1 35 Table 6 Wiegand 26 Mode 2 35 Table 7 Wiegand 26 Mode...

Page 5: ...N HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUEL...

Page 6: ...cation system designed to ensure low cost simple to install use reliable and single box solution for intercom application It is designed for unlimited range wire free GSM intercom pin code access call...

Page 7: ...es Caller ID numbers control up to 1000 caller ID numbers Up to 100 temporary SPIN access codes Input Wiegand receiver up to 1000 receivers 2 outputs relay supported Programming with PC via USB to Min...

Page 8: ...re inserting SIM card to unit make sure the PIN code is removed Insert SIM card in EIS unit Connect power cable to EIS unit YOU MUST POWER THE EIS UNIT WITH THE POWER SUPPLY INCLUDED Do not power with...

Page 9: ...al from 1 to 5 LED flashes 1 is weak signal 5 is excellent signal Red LED LED2 GSM module Activity Yellow LED LED3 Short flashing indicates that the GSM module is ON but it is not yet connected on the...

Page 10: ...9 6 CONNECTION DIAGRAM Before connection the EIS please take a look at connection diagram Figure 1 EIS Connection diagram IMPORTANT DO NOT USE Power out 12V AUX for electric lock driving Use separate...

Page 11: ...er access Access it by EISWARE com EISWARE APP on IPHONE or ANDROID Must have data plan enabled to get data transfer on either method These are alternative solutions to accomplish the programming Unit...

Page 12: ...be able to use WEB programming 8 1 WEB SERVER LOG IN The web server can be find under the address https www eisware com Figure 2 WEB Server Sign In page User must first use the Sign IN section to cre...

Page 13: ...NITS TO USER PROFILE After login the user will be diverted to WEB server main window This page is used to add remove search for EIS units from the user s profile Select sign to select ADD EIS units to...

Page 14: ...ld be on the card board box of the EIS Phone Number The telephone number of the SIM card in the EIS unit mandatory data GPRS settings Information needed to enable data connection between the server an...

Page 15: ...nge the configuration of the specific unit All changes made by the user are listed in the Change Log window By clicking Send to device button ALL changes are send to the unit User can Revert all chang...

Page 16: ...ed the unit will stop dialing next numbers on the list To terminate the call press any button Management of the intercom function is found under Intercom tab Figure 6 WEB Server Intercom settings Inte...

Page 17: ...ing the level will increase the volume of the unit speaker decreasing will decrease the level of the speaker Ringing sound By selecting Playing the unit will play the dial tone in the connection phase...

Page 18: ...de and second is temporary pin codes which are limited by the consecutive time they are entered Permanent pin codes are placed in Pin access tab They are placed in two tables For each table user can d...

Page 19: ...PIN code User name Name of the user Notify If SPIN code is used administrator numbers CAN be notified Counter limit Enable Disable counter limitation consecutive use Timer limit Enable Disable timer...

Page 20: ...on board with a dedicated Wiegand connector and cables Figure 9 WEB Server First Wiegand interface support Mode Select appropriate data formatting Advise unit provider for more info if needed mode 2 i...

Page 21: ...if needed mode 2 is most common setting Facility code User can Enable or Disable facility code field Wiegand devices can be defined in two section First section is permanent pin codes and second is te...

Page 22: ...ller ID Disabled deactivates caller ID function all numbers are restricted Caller ID for specific users will limit the caller ID function only to the numbers on the list Caller ID always ON will allow...

Page 23: ...entry will activate the output second Caller ID or PIN entry will deactivate the output Time Pulse Output is time pulse mode After output is triggered it will be activated for the time defined in Outp...

Page 24: ...ons are closed Additional output settings Setting are used to link onboard actions with the outputs if needed Voice active indication When unit reaches voice connection intercom call output defined un...

Page 25: ...WEB Server Wiegand Output settings Configuration of the Wiegand output interface Wiegand Type Type of the Wiegand used W26 is most common setting Data format Format of data set on the selected Wiegand...

Page 26: ...tures 2 timers that can be used to control the outputs on the unit Timers can run in day or week mode depending on the selected setting For each timer user can select which output it will control Figu...

Page 27: ...ior of the outputs Time pulse or Latching mode is defined in the Output tab Master mode When the output is driven by the timer output is activated by the timer the outputs are in latching mode regardl...

Page 28: ...name of the user that will be receiving notification messages Input1 Input2 If input lines 1 2 are defined in alarm mode Input operation mode Normal mode and if alarm condition is meet users with che...

Page 29: ...a critical full level Notify event Selection of administrators that will be notified if the notification event is enabled in Temporary pin access tab or Pin access tab Administration allowed to remot...

Page 30: ...vents unit can CLEAR events or STOP recording new events Event logging User can select between not logging logging to internal memory unit or optional sending events over units USB connection to the e...

Page 31: ...rval User can select GSM module restart interval hours if needed Not advisable to use this parameter if not advised otherwise Self updating clock Parameter is used to allow unit to synchronize to real...

Page 32: ...on function is done in 2 Steps STEP 1 User has to select Enable option in the Enable Pin Notification function STEP 2 Send the configuration to the device This procedure is ONLY done 1 time when enabl...

Page 33: ...that will be receiving the notification SMS Selecting is done in the Administration tab In the Notify PIN column put a tick in the check box for the appropriate phone number multiple choices are possi...

Page 34: ...l possible management systems Selecting the appropriate data format for FIRST Wiegand interface is done by connecting the WEB server selecting the Digital interface and in Input section selecting prop...

Page 35: ...EIS 1 EIS 2 EIS 4 USER MANUAL Page 34 Figure 23 WEB Server Second Wiegand interface support...

Page 36: ...B B B B B B P Parity 8Bit card facility number 16Bit card number Parity Limits Card Number 0 16777215 Facility Number NOT USED Table 4 Wiegand 26 Mode 1 Mode 2 24bit of data is divided between facili...

Page 37: ...B B P Parity Not used 8Bit facility number 16Bit card number Parity Limits Card Number 0 16777215 Facility Number NOT USED Table 8 Wiegand 30 Mode 1 Mode 2 28bit of data is divided between facility c...

Page 38: ...EIS 1 EIS 2 EIS 4 USER MANUAL Page 37...

Reviews: