PSV-2/14-45 IN THE NETWORK

The PowerStar™ V allows various host input connection options.
When the PowerStar™ V is within approximately 460 meters (2 Mb/s
Express mode) or 760 meters (1 Mb/s standard mode) of the host, the
link from the host to the PowerStar™ V can be made by installing a
twinax balun at the host and then connecting twisted-pair cable
between the twinax balun and one of two RJ-45 LINK connectors at the
front of the PowerStar™ V. A second connection can be made to the
second RJ-45 LINK connector.
When the PowerStar™ V is within approximately 1200 meters (2 Mb/s
Express mode) or 1520 meters (1 Mb/s standard mode) of the host, if the
optional twinax slide-in-card (SIC), PS-T-SIC, is installed in the
PowerStar™ V, the link from the host to the PowerStar™ V can be made
by connecting twinax cable between the host and one of two (2) twinax
connectors on the slide-in-card at the back of the PowerStar™ V.  A
second connection can be made to the second twinax connector on the
slide-in-card.
When the PowerStar™ V is within approximately 3000 meters (2 Mb/s
Express mode OR 1 Mb/s standard mode) kilometers of the host, if the
optional fiber slide-in-card, PS-T-SIC, is installed in the PowerStar™ V
and a compatible twisted-pair/fiber media converter (such as the
TRANSITION Networks IBM® 5250) is available, the link from the host
to the PowerStar™ V can be made by installing a twinax balun at the
host, then connecting twisted-pair cable between the balun and the
media converter, and then connecting fiber from the media converter to
one of two (2) fiber connectors on the slide-in-card at the back of the
PowerStar™ V.  A second connection can be made to the second fiber
connector on the slide-in-card.
When the PowerStar™ V is within approximately 3000 meters of the
host, if the optional twinax slide-in-card is installed in the PowerStar™
V and a compatible twisted-pair/fiber media converter (such as the
TRANSITION Networks IBM® 5250) is available, the link from the host
to the PowerStar™ V can be made by installing a twinax balun at the
host, then connecting twisted-pair cable between the balun and the
media converter, connecting fiber from the media converter to a`second
media converter, installing another twinax balun on the twinax slide-in-
card, then connecting twisted-pair cable between the media converter
and the balun. A second connection can be made to the second twinax
connector on the slide-in-card.
Connection from the PowerStar™ V to terminal devices is through
twisted-pair copper cable and RJ-45 connectors.

TECHNICAL SPECIFICATIONS

Host Connection

IBM

®

S/3x (System 34, 36, 38), AS/400™ Host or

AS/400

Controllers

Dimensions

17.0" x 7.5" x 1.7" 

(432 mm x 191 mm x 43 mm)

Power

Input Range:

85 to 265 VAC at 47 to 63 Hz. Rated at 40 watts
maximum.

Power Cord:

TN PN

Requirement

Location

3344

120 volts, 60 hertz

USA/Canada/Mexico

3344

100 volts, 50-60 hertz

Japan

3347

230 volts, 50 hertz

Europe

3348

240 volts, 50 hertz

Australia

3349

240 volts, 50 hertz

United Kingdom

Environment

Temperature:

0-50°C (32° to 122° F )

Humidity

10-95%, non condensing 

Altitude

0-10,000 feet

Storage Temperature

-40 to 85C (-40 to 185F)* 

*Must be stable within operating environment limits before powering on. 

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

PowerStar

Part Number:

PSV-2/14-45

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the PSV-2/14-45 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_September 30, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for PSV-2/14-45

Page 1: ...s All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S...

Page 2: ...stalled in the PowerStar V and a compatible twisted pair fiber media converter such as the TRANSITION Networks IBM 5250 is available the link from the host to the PowerStar V can be made by installing...

Page 3: ...ometers 10 000 feet Actual distance dependent upon physical characteristics of network installation ST CONNECTOR AS 400 S 3x or 5x94 up to 762 meters 1 Multimode up to 2 kilometers Singlemode up to 8...

Page 4: ...slide in card thumbscrews into PowerStar V threaded holes CABLE SPECIFICATIONS Twisted Pair Cable and Connector Specifications Category 3 OR BETTER twisted pair copper wire is required Either shielded...

Page 5: ...al shock WARNING AVOID CONTACT WITH POWER SUPPLY during jumper pin setting Failure to observe this warning could result in personal injury or death from electrical shock caused by capacitive discharge...

Page 6: ...wer ON the PowerStar V 1 At PowerStar V back locate the power receptacle and associated fuse 2 Verify that fuse is installed at correct rating setting for power source voltage The installed fuse ratin...

Page 7: ...g the site installation handle the PSV 2 14 45 in such a way that the PSV 2 14 45 does not fall Failure to observe this warning could result in injury to personnel and or equipment damage NOTE If PSV...

Page 8: ...to AS 400 Sys 36 or 5x94 controller port 4 Connect other end of twinax cable to twinax port connector on slide in card 5 Optionally connect second twinax cable to second twinax port connector on twina...

Reviews: