INSTALLATION 

Set Twisted-Pair Polarity Switches

Two (2) sets of twisted-pair polarity switches at the
PowerStar™ V front toggle the polarity of the active
RJ-45 pins for each host Link and for each set of
seven device Ports
.  

Set the factory default host Link switch to "A"
when connecting twinax cable to the host.  

Set the host Link switch and the device Ports
switch for twisted-pair copper to "A" or to "B"
according to the pin settings and baluns
(TRANSITIION Networks or other) used at the RJ-45
port connectors:

NOTE: TRANSITION Networks
baluns listed in the table to the
left are coded as: “3-XXxx”,
where XX represents the twisted-
pair port connector (45 = RJ-45)
and xx represents the order of the
active pins (12 = 1 & 2,  21 = 2
& 1, 36 = 3 & 6, 63 = 6 & 3, 
45 = 4 & 5, 54 = 5 & 4.

Optionally Install Slide-In-Card (SIC)

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing slide-in cards. Failure to observe this caution
could result in circuit board failure.

To install a slide-in-card:

1.

With slide-in-card components facing up,
carefully guide slide-in-card along
card guides until connector
on slide-in-card
meets internal
PowerStar™
V edge
connector.

2.

Firmly push card into slot until
slide-in-card faceplate is flat against
PowerStar™ V frame.

3.

Rotate two slide-in-card thumbscrews into
PowerStar™ V threaded holes. 

CABLE SPECIFICATIONS

Twisted Pair Cable and Connector Specifications

Category 3 OR BETTER twisted-pair copper wire is required. Either
shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.
DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 3 CABLE

Gauge

24 to 22 AWG

Attenuation 

-11.5 dB/100m @ 5-10 MHz

MINIMUM CABLE DISTANCE

7.6 meters (25 feet)

Typical Maximum Cable Distance*:

1 Mb/s

760 meters (2500 feet)

2 Mb/s

460 meters (1500 feet)

*Actual distance dependent upon physical characteristics of network installation.

RJ-45 CONNECTOR

Twisted pair connection requires one active pair configured as straight
through. Using RJ-45 connectors, the active pair can be pins 1 & 2, pins
4 & 5 or pins 3 & 6.

Twinax Cable and Connector Specifications

TWINAX CABLE 

Twinax cable consists of conductors - one tinned and one solid copper -
in a tinned copper braid shield, with impedance of 100 ohms.

Cable Type

IBM PN or equivalent

Twinax Plenum

7362061

Twinax PVC

7362211

MINIMUM CABLE DISTANCE

7.6 meters (25 feet)

Typical MAXIMUM CABLE DISTANCE*:

1 Mb/s

1520 meters (5,000 feet)

2 Mb/s

1200 meters (4.000 feet)

*Actual distance dependent upon physical characteristics of network installation.

NOTE: The last twinax connection in a daisy-chain must be terminated.

Parity Error

B

A

Right

Left

Polarity
Settings

Ports

Link

Ports

Link

Setting

Pins

TN Balun

A

2 & 1

3-4521

A

6 & 3

3-4563

5 & 4

3-4554

B

1 & 2

3-4512

B

3 & 6

3-4536

B

4 & 5

3-4545

Summary of Contents for PSV-2/14-45

Page 1: ...s All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S...

Page 2: ...stalled in the PowerStar V and a compatible twisted pair fiber media converter such as the TRANSITION Networks IBM 5250 is available the link from the host to the PowerStar V can be made by installing...

Page 3: ...ometers 10 000 feet Actual distance dependent upon physical characteristics of network installation ST CONNECTOR AS 400 S 3x or 5x94 up to 762 meters 1 Multimode up to 2 kilometers Singlemode up to 8...

Page 4: ...slide in card thumbscrews into PowerStar V threaded holes CABLE SPECIFICATIONS Twisted Pair Cable and Connector Specifications Category 3 OR BETTER twisted pair copper wire is required Either shielded...

Page 5: ...al shock WARNING AVOID CONTACT WITH POWER SUPPLY during jumper pin setting Failure to observe this warning could result in personal injury or death from electrical shock caused by capacitive discharge...

Page 6: ...wer ON the PowerStar V 1 At PowerStar V back locate the power receptacle and associated fuse 2 Verify that fuse is installed at correct rating setting for power source voltage The installed fuse ratin...

Page 7: ...g the site installation handle the PSV 2 14 45 in such a way that the PSV 2 14 45 does not fall Failure to observe this warning could result in injury to personnel and or equipment damage NOTE If PSV...

Page 8: ...to AS 400 Sys 36 or 5x94 controller port 4 Connect other end of twinax cable to twinax port connector on slide in card 5 Optionally connect second twinax cable to second twinax port connector on twina...

Reviews: