background image

3.

To disengage cover from chassis, slide PowerStar™ V cover
approximately one-inch toward back of the PowerStar™ V. 

4.

Carefully lift PowerStar™ V cover and remove.

5.

Using needle nose pliers with insulated handle and referring to
reference diagram on the previous page, move jumpers as required
to change factory default active pin settings to active pin settings for
the site.

6.

Replace PowerStar™ V cover on chassis, sliding cover forward to
engage cover against chassis.

7.

Replace retained cover screws.

Power the PowerStar™ V

NOTE: Fuse must be installed at correct setting for power source voltage
before connecting to AC outlet.

To power ON the PowerStar™ V:

1.

At PowerStar™ V back, locate the power receptacle and associated
fuse.

2.

Verify that fuse is installed at correct rating setting for power source
voltage. (The installed fuse rating is indicated by the reading at
lower right corner of fuse holder.) 

If not installed at correct setting for power source voltage: 

Carefully open fuse receptacle, using a small flat blade
screwdriver. 

Rotate fuse holder 180° to the correct rating orientation.

Install fuse holder in correct rating orientation.

Close fuse receptacle.

3.

Plug unit end (female) of power cord into PowerStar

V power

receptacle.

4.

Plug outlet end (male) of power cord into correct voltage AC wall
socket.

5.

At PowerStar™ V front, verify that POWER LED is illuminated. 

110-120

110-120

220-240

220-240

Fuse Holder

Fuse Holder

110-120 Orientation

220-240 Orientation

Summary of Contents for PSV-2/14-45

Page 1: ...s All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S...

Page 2: ...stalled in the PowerStar V and a compatible twisted pair fiber media converter such as the TRANSITION Networks IBM 5250 is available the link from the host to the PowerStar V can be made by installing...

Page 3: ...ometers 10 000 feet Actual distance dependent upon physical characteristics of network installation ST CONNECTOR AS 400 S 3x or 5x94 up to 762 meters 1 Multimode up to 2 kilometers Singlemode up to 8...

Page 4: ...slide in card thumbscrews into PowerStar V threaded holes CABLE SPECIFICATIONS Twisted Pair Cable and Connector Specifications Category 3 OR BETTER twisted pair copper wire is required Either shielded...

Page 5: ...al shock WARNING AVOID CONTACT WITH POWER SUPPLY during jumper pin setting Failure to observe this warning could result in personal injury or death from electrical shock caused by capacitive discharge...

Page 6: ...wer ON the PowerStar V 1 At PowerStar V back locate the power receptacle and associated fuse 2 Verify that fuse is installed at correct rating setting for power source voltage The installed fuse ratin...

Page 7: ...g the site installation handle the PSV 2 14 45 in such a way that the PSV 2 14 45 does not fall Failure to observe this warning could result in injury to personnel and or equipment damage NOTE If PSV...

Page 8: ...to AS 400 Sys 36 or 5x94 controller port 4 Connect other end of twinax cable to twinax port connector on slide in card 5 Optionally connect second twinax cable to second twinax port connector on twina...

Reviews: