Transition Networks Milan MIL-RCM16A-V2 User Manual Download Page 8

 

Software Upgra

de 

Firmware upgrade by Web interface and TFTP 

Link Loose 

Forward   

Each module supports LLF feature. It can be set by 

Web or CLI menu 

LLF Mode TX 

  Fiber: TX

 port link down, the fiber 

port will be forced down 

LLF Mode Fiber 

  TX : Fiber port link down, the 

TX port will be forced down 

Packet counter 

TX port: IN-good / In-bad packet counter 

out-good /out-bad packet counter 

collision counter 

Fiber port: IN-good / In-bad packet counter 

out-good /out-bad packet counter 

SNMP Trap Node 

Up to 4 Trap nodes 

IP security 

IP security for telnet 

HTTP and SNMP access 

Up to 4 IP nodes when security is enabled 

TS-1000   

Loop back test, remote configuration 

SNTP 

RFC2030 Simple Network Time Protocol 

Events log 

Up to 4095 event records. It can be reviewed

 by CLI 

and Web browser mode 

 

 

 

 

Summary of Contents for Milan MIL-RCM16A-V2

Page 1: ...Raven Series Modular Media Converter System MIL RCM16A V2 16 Slot Raven Conversion Modules Managed Chassis with AC Power Supply USER GUIDE...

Page 2: ...original consumer or purchaser and is not assignable Transition Networks makes no express or implied warranties including but not limited to any implied warranty of merchantability or fitness for a pa...

Page 3: ...n a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try...

Page 4: ...ysical Description 6 Front Rear Panel 6 LED Indicators 7 System Cabinet 7 Connecting to the Network 10 Pre Installation Requirements 10 Mounting the Device 10 Desktop Installation 11 Attaching Rubber...

Page 5: ...Settings Reboot System 24 Reboot System 25 TFTP Configuration 25 Web Based Management 26 About Web based Management 26 System Login 27 Modules settings 29 Port Counter 34 IP Config 35 SNMP 36 Event Lo...

Page 6: ...ement managing and configuring the 16 Slots intelligent converter chassis becomes easier Users can visually configure and manage their network via the Web browser Besides the 16 Slots intelligent conv...

Page 7: ...ed SNMP MIB II and private MIB supported Supports Simple Network Time Protocol SNTP Power and Fan Detect Loop Back Test EIA RS 310C 19 standard Software Feature Management Telnet Web Console RS 232 We...

Page 8: ...down Packet counter TX port IN good In bad packet counter out good out bad packet counter collision counter Fiber port IN good In bad packet counter out good out bad packet counter SNMP Trap Node Up...

Page 9: ...ent converter chassis provides an embedded HTML web program in flash memory It offers advanced management features and allows users to manage the 16 Slots intelligent converter chassis from anywhere o...

Page 10: ...s Power Cord Four Rubber Pads RS 232 cable User Manual 16 Slots intelligent converter chassis Rubber Pads Rack mounted Kit RS 232 cable User Manual Power Cord Package Contents Compare the contents of...

Page 11: ...erter chassis and gives a physical and functional overview on certain module converter Physical Description The physical dimensions of the 16 Slots intelligent converter chassis is 448mm x 279mm x 89m...

Page 12: ...Rear Panel of the 16 Slots intelligent converter chassis LED Indicators All LED status indicators are located on the front panel of the modules They display real time indication of system and operatio...

Page 13: ...rrectly PWR Green Power on Green Power Module A Ready Good A Off Power Module A Not Ready Green Power Module B Ready Good B Off Power Module B Not Ready Orange Power Module A Fail Fail A Off Power Mod...

Page 14: ...is connected with the device LK ACT Blink The port is receiving or transmitting data Yellow Ethernet is linked with Full Duplex mode FDX Blink Collision of Packets occurs in the port Descriptions of t...

Page 15: ...er outlet 100 to 240V AC at 50 to 60 Hz Make sure that the Device power is accessible and cables can be connected easily Dedicated power supply Use dedicated power circuits or power conditioners to su...

Page 16: ...2 Remove adhesive backing from Rubber Pads 3 Apply the Rubber Pads to each corner on the bottom of the device These footpads can prevent the device from shock vibration Attaching Rubber Pads to each c...

Page 17: ...and the rack mounting screws Mount the converter chassis in an EIA standard 19 inch Rack NOTE For proper ventilation allow at least 4 inches 10 cm of clearance on the front and 3 4 inches 8 cm on the...

Page 18: ...CPU LED always light on it means system crash Connecting the Device via Local console or Telnet The serial console port is a male DB 9 connector that enables the connection from PC or terminal for mo...

Page 19: ...onsole port Baud Rate 9600 bps Data Bits 8 Stop Bit 1 Parity none Flow control None The setting of communication parameters Run Hyper Terminal or a terminal emulation program using the above settings...

Page 20: ...15 The Main Menu...

Page 21: ...elect Device settings Type 1 and press Enter from the main menu It displays the list of device settings items ex system name location IP and so on User can enter the number to modify the value Device...

Page 22: ...NTP Config Configuring the SNTP Simple Network Time Protocol settings The SNTP allows user to synchronize switch clocks in the Internet 1 Enable Disable Sntp Client To enable or disable SNTP function...

Page 23: ...converter modules Input 2 and press Enter at main menu interface The system will guide the user to select the module for configuration Enter the number of module ex 1 and then press Enter After enter...

Page 24: ...t Speed Duplex Configuring RJ 45 port speed and mode The default is 10M Half 4 Fiber Port Speed Duplex Configuring Fiber port speed and mode The default is 10M Half 5 Reset to default To reset the mod...

Page 25: ...Back Test Checking the fiber port connection status between remote and central site converter automatically 5 Bandwidth rate control Terminal Tx port Config Bandwidth rate control terminal UTP port 6...

Page 26: ...Event Log Enabled The System will start record events when it is enable 2 Show Event Log For viewing event log records To enable Event Log Enable function 3 Delete All Event Log Removing all event log...

Page 27: ...s Only the authorized station can receive the Trap information Q Quit Exit from the current interface SNMP Trap interface Secure IP for Telnet HTTP and SNMP Configuring security management for Telnet...

Page 28: ...gh Telnet HTTP and SNMP Q Quit Exit from the current interface Port Counters Viewing UTP and fiber port counter information 1 RJ 45 Viewing all the UTP port counter information 2 Fiber Viewing all fib...

Page 29: ...ter key There are three optional selections that user can decide to set back to default value or keep current value Module settings User might keep current configure value when the system set to facto...

Page 30: ...and press Enter key TFTP Configuration Use TFTP function to update the firmware 1 Set TFTP Server IP set up the TFTP server IP address 2 Set File Name set up the firmware file name 3 Update Firmware e...

Page 31: ...network bandwidth consumption enhance access speed and present an easy viewing screen NOTE By default IE5 0 or later version does not allow Java Applets to activate sockets In fact the user has to ex...

Page 32: ...below to login system 1 Start Internet Explorer 2 Key in http the IP address of the 16 Slots intelligent converter chassis for example the Factory default is 192 168 16 77 and press Enter key The auth...

Page 33: ...unit that can be modified in SNMP page Location The physical location of this managed unit e g laboratory 3rd floor that can be modified in SNMP page Contact The contact person for this managed unit t...

Page 34: ...ower status Display the redundant power status Firmware Version The firmware version of the management unit It is read only User can online upgrade the new firmware if the new version is released Hard...

Page 35: ...tion button to configure the TS 1000 function LLF enable disable When the RJ 45 or Fiber is link down it will force the other port disconnect automatically The forced way is depends on the RJ 45 contr...

Page 36: ...mode 100Mbps or 10 Mbps Duplex When the port negotiation is in force mode user can configure duplex mode half or full Auto Negotiation Configure the negotiation mode auto or force Bandwidth Input Rat...

Page 37: ...the output bandwidth rate 10 100Mbps 2 5 25Mbps 5 50Mbps or 7 5 75Mbps Terminal TS 1000 reset default Set the configuration back to the default settings And then click Apply to apply the configuration...

Page 38: ...the speed Default Force means the user can select the speed Speed Select the speed of port Make sure the Nego column is set as Force Otherwise the speed function will be disable Duplex Select the Dup...

Page 39: ...mitted R means RJ 45 port Tx Collision R Amount of transmit collision R means RJ 45 port Rx Collision R Amount of receive collision R means RJ 45 port Rx Good Pkts F Amount of good packets has receive...

Page 40: ...dress subnet mask and default gateway Just simply fill in the new IP address subnet or default gateway in corresponding column Then click Apply to have the configuration taken effect Users should rebo...

Page 41: ...pply to have the settings taken effect There are up to 4 trap management stations could set to receive the trap packets from the 16 slot chassis converter Check marks the send traps to the following m...

Page 42: ...logs Click Enable to enable the event log function Or press Refresh to get the event logs The system will not auto refresh the event log To stop the event log function click Disable To clear all even...

Page 43: ...ess Sntp Server 2 IP Set the SNTP server IP address Sntp Server 3 IP Set the SNTP server IP address UTC Timezone Set the switch location time zone Enable Disable Daylight Saving To enable or disable d...

Page 44: ...mum of length is 15 characters Confirm Password Re enter the new password for confirmation Misc Settings Interface Security IP Configure security management for Telnet Web management and SNMP and the...

Page 45: ...t settings will be executed automatically Factory Default Settings Reboot To use the factory default settings check the Factory Default Settings reboot checkbox then click the Apply There are two opti...

Page 46: ...ersion of firmware from vendor web site 2 Enter password in the Password box Please note that the default password is root and it follows the user password change it could be changed by individual use...

Page 47: ...pdate the firmware 1 TFTP Server IP set up the TFTP server IP address 2 File Name set up the firmware file name 3 Click the Tftp Upgrade button to start updating Help In each configuration section use...

Page 48: ...and SET commands And the SNMP agent that resides on the device can respond to MIB related queries being sent by the network management software The SNMP agent gathers data from the MIB which keeps in...

Page 49: ...est of SNMP objects in the device SET Modify and store values of SNMP objects in a network device GET RESPONSE Replying the GET GETNEXT and SET commands are sent by SNMP agent TRAP A message sent by a...

Page 50: ...plex ST SC Simplex SC WDM single mode RJ 45 CAT 5 10 100Mbps Twisted Pair cable Gigabit Module Fiber Duplex SC Single mode 10KM Multi mode 500Meters RJ 45 CAT 5 1000Mbps 4 pairs of UTP STP cable CPU B...

Page 51: ...NI GBIC module Power Gigabit Copper Speed 1000Mbps LK ACT FDX COL Fiber Link Act FDX COL Fiber parameters Fiber Core Multi Mode 62 5 125um 50 125um Single Mode 9 125 m Wavelength 100Mbps multi mode 13...

Page 52: ...for Non VLAN Ethernet packet 68 to 1522 Bytes for VLAN Tag type Ethernet packet Dimensions 448mmx 279mm x 89mm W x D x H Operational Temperature 0 C to 45 C 32 F to 113 F Transparent packet 64 to 151...

Reviews: