Power the E-FL-HB-0x00

NOTE: When the hub is connected to an AC outlet supplying 100-240VAC at
50-60 Hz, the hub automatically powers ON 

To power ON the E-FL-HB-0x00:

1.

Locate power receptacle at back of E-FL-HB-0x00.

2.

Plug unit end (female) of power cord into E-FL-HB-0x00 power
receptacle.

3.

Plug outlet end (male) of power cord into correct voltage AC wall
socket.

4.

At E-FL-HB-0x00 front, verify that P(o)W(e)R LED is illuminated. 

4.

Connect AUI drop cable female connector to the AUI port on a
10BASE-5 cable transceiver or media attachment unit (MAU).

5.

Verify that 10BASE-5 segment is terminated at both ends using
50-ohm terminators.

THROUGH BNC UPLINK

NOTE: Refer to 5-4-3 rule (page 3) to keep network configuration within
acceptable bounds.

NOTE: In a coax thinnet installation, the first and last device in the
daisy-chain must be terminated using a 50 ohm terminator. Additionally,
the 10BASE-2 segment must be grounded to “earth ground” at one end.

To connect to 10BASE-2 network:

1.

Locate BNC uplink adapter installed at E-FL-HB-0x00 back (See
page 4.) 

2.

Locate or build IEEE 802.3 compliant 10BASE-2 cable and male
BNC T-connector. (See page 14.)

3.

Install the mating T-connector to the female BNC connector on
the E-FL-HB-0x00

4.

Install 10BASE-2 cable at one side of the T-connector.

5.

Install 10BASE-2 cable at other side of T-connector OR, if the
E-FL-HB-0x00 is the last network device in the daisy chain,
install 50-ohm terminator.

6.

Verify that the 10BASE-2 segment coax cable segment is
terminated properly at both ends.

STAT

10BASE-FL

1

2

3

4

5

6

7

8

PWR

COL

ACT

BB

1

3

2

4

5

7

6

8

50

 Terminator

Earth Ground

50

 Terminator

Summary of Contents for E-FL-HB-0400

Page 1: ...imits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European...

Page 2: ...DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model E FL HB 0x00 Series Unmanaged Fiber Hub Part Number E FL HB 0800 E FL HB 0800 SC E FL HB 0400 E FL HB 0400 SC Regulation EMC Directive 89 336 EEC Purpose To declare that the E FL HB 0800 or E FL HB 0400 to which this declaration refers is in conformity with the following standards EMC CI...

Page 3: ... Coaxial RG58 ThinNet Impedance 50 Ω 10 MHz Mutual Capacitance 24 pF ft 20 10 MHz Maximum Cable Length 185 meters 610 feet Maximum number network connections 30 Minimum distance between connections 0 5 meters 1 6 feet Terminate 10BASE 2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground AUI 10BASE 5 Cable Specifications 10BASE 5 CABLE...

Page 4: ...t against E FL HB 0x00 chassis 5 Secure backbone uplink adapter by installing retained screws through backbone uplink adapter into E FL HB 0x00 chassis 6 Is the B ack B one ACT ivity LED illuminated NO Disconnect and reconnect the backbone cable to restart the initialization process Restart the attached network device to restart the initialization process Contact Technical Support 800 260 1312 YES...

Page 5: ...LINKAlert is NOT enabled the port is partitioned investigate the device at the far end of the link If the fiber backbone adapter plate is installed and LINKAlert IS enabled determine and correct the cause of the Far End Fault Contact Technical Support 800 260 1312 NO Continue at step 6 Install E FL HB 0x00 at Site WARNING During the site installation handle the E FL HB 0x00 in such a way that the ...

Page 6: ...00 OPERATION Use the status LEDs to monitor E FL HB 0x00 operation in the network E FL 0X00 HUB INDICATORS P o W e R Steady LED indicates E FL HB 0x00 is connected to external AC power COL lision Flashing LED indicates network collisions B ACK B ONE INDICATORS STAT us Steady LED indicates for network connection a valid link and no partition or isolation One 1 continuous flashing blink indicates ne...

Page 7: ...ion within acceptable bounds NOTE In a coax thinnet installation the first and last device in the daisy chain must be terminated using a 50 ohm terminator Additionally the 10BASE 2 segment must be grounded to earth ground at one end To connect to 10BASE 2 network 1 Locate BNC uplink adapter installed at E FL HB 0x00 back See page 4 2 Locate or build IEEE 802 3 compliant 10BASE 2 cable and male BNC...

Page 8: ... Locate or build 10BASE FL compliant two stranded fiber cable with appropriate male TX to RX connectors installed at both ends 2 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on front of one hub 3 Connect male TX and RX cable connectors at other end of cable to RX and TX connectors respectively on front of second hub Connect E FL 0x00 Hub t...

Reviews: