INSTALLATION 

Optionally Install Backbone Uplink Adapter

WARNING: Remove AC line cord from power source before installing
backbone uplink adaptor in E-FL-HB-0x00. Failure to observe this warning
could result in personal injury or death.

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing backbone uplink adaptor in the E-FL-HB-0x00.
Failure to observe this caution could result in damage to, and subsequent
failure of, backbone uplink adaptor.

To install the backbone uplink adapter in the E-FL-HB-0x00:

1.

Locate backbone uplink adapter plate at back of E-FL-HB-0x00.

2.

Remove backbone uplink adapter plate by using flatblade
screwdriver to remove two (2) screws that secure backbone uplink
adapter plate to back of E-FL-HB-0x00.

NOTE: Retain screws for step 5. (Optionally discard backbone
uplink adapter plate.)

3.

Carefully slide backbone uplink adapter, component side up, into
installation space revealed by removal of backbone uplink adapter
plate.

CAUTION: Do NOT force connection. Failure to observe this caution

could result in equipment damage and subsequent failure.

4.

Press component on backbone uplink adapter securely against
internal mating E-FL-HB-0x00 component until backbone uplink
adapter faceplate is flat against E-FL-HB-0x00 chassis.

5.

Secure backbone uplink adapter by installing retained screws
through backbone uplink adapter into E-FL-HB-0x00 chassis.

6.

Is the B(ack)B(one) ACT(ivity) LED illuminated?
NO

Disconnect and reconnect the backbone cable to restart the
initialization process.

Restart the attached network device to restart the initialization
process.

Contact Technical Support: (800) 260-1312.

YES

Continue at step 7.

7.

Is one (or more) of the 10BASE-FL STAT(us) LEDs illuminated
continuously?
YES

Continue at step 10.

NO

Continue at step 8.

8.

Does one (or more) of the 10BASE-FL STAT(us) LEDs
continuously blink ONCE?
YES

Check fiber cables for proper connection.

Verify that TX and RX cables on E-FL-HB-0x00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)

Ensure that terminal device(s) is/are powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 9.

9.

Does one (or more) of the 10BASE-FL STAT(us) LEDs
continuously blink TWICE?
YES

The port is (or ports are) partitioned; investigate the attached
terminal device(s).

Contact Technical Support: (800) 260-1312.

NO

Continue at step 10.

10.

Is one (or more) of the 10BASE-FL ACT(ivity) LEDs illuminated?
YES

The port is (or ports are) operational and receiving data.

NO

Disconnect and reconnect the 10BASE-FL cable to restart the
initialization process.

Restart the terminal device(s) to restart the initialization process.

Contact Technical Support: (800) 260-1312.

Backbone Uplink Adapter Plate

Summary of Contents for E-FL-HB-0400

Page 1: ...imits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European...

Page 2: ...DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model E FL HB 0x00 Series Unmanaged Fiber Hub Part Number E FL HB 0800 E FL HB 0800 SC E FL HB 0400 E FL HB 0400 SC Regulation EMC Directive 89 336 EEC Purpose To declare that the E FL HB 0800 or E FL HB 0400 to which this declaration refers is in conformity with the following standards EMC CI...

Page 3: ... Coaxial RG58 ThinNet Impedance 50 Ω 10 MHz Mutual Capacitance 24 pF ft 20 10 MHz Maximum Cable Length 185 meters 610 feet Maximum number network connections 30 Minimum distance between connections 0 5 meters 1 6 feet Terminate 10BASE 2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground AUI 10BASE 5 Cable Specifications 10BASE 5 CABLE...

Page 4: ...t against E FL HB 0x00 chassis 5 Secure backbone uplink adapter by installing retained screws through backbone uplink adapter into E FL HB 0x00 chassis 6 Is the B ack B one ACT ivity LED illuminated NO Disconnect and reconnect the backbone cable to restart the initialization process Restart the attached network device to restart the initialization process Contact Technical Support 800 260 1312 YES...

Page 5: ...LINKAlert is NOT enabled the port is partitioned investigate the device at the far end of the link If the fiber backbone adapter plate is installed and LINKAlert IS enabled determine and correct the cause of the Far End Fault Contact Technical Support 800 260 1312 NO Continue at step 6 Install E FL HB 0x00 at Site WARNING During the site installation handle the E FL HB 0x00 in such a way that the ...

Page 6: ...00 OPERATION Use the status LEDs to monitor E FL HB 0x00 operation in the network E FL 0X00 HUB INDICATORS P o W e R Steady LED indicates E FL HB 0x00 is connected to external AC power COL lision Flashing LED indicates network collisions B ACK B ONE INDICATORS STAT us Steady LED indicates for network connection a valid link and no partition or isolation One 1 continuous flashing blink indicates ne...

Page 7: ...ion within acceptable bounds NOTE In a coax thinnet installation the first and last device in the daisy chain must be terminated using a 50 ohm terminator Additionally the 10BASE 2 segment must be grounded to earth ground at one end To connect to 10BASE 2 network 1 Locate BNC uplink adapter installed at E FL HB 0x00 back See page 4 2 Locate or build IEEE 802 3 compliant 10BASE 2 cable and male BNC...

Page 8: ... Locate or build 10BASE FL compliant two stranded fiber cable with appropriate male TX to RX connectors installed at both ends 2 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on front of one hub 3 Connect male TX and RX cable connectors at other end of cable to RX and TX connectors respectively on front of second hub Connect E FL 0x00 Hub t...