Optionally Connect to Backplane 

THROUGH AUI UPLINK

NOTE: Refer to 5-4-3 rule (page 3) to keep network configuration within
acceptable bounds.

USING TRANSCEIVER

NOTE: Refer to transceiver documentation for detailed
specifications and instructions.

1.

Locate AUI uplink adapter installed at E-FL-HB-0x00 back. (See
page 4.) 

2.

Locate IEEE 802.3 compliant transceiver with male AUI
connector and with required network media connector.

3.

Connect transceiver male AUI connector to the female AUI
connector on E-FL-HB-0x00

4.

Referring to transceiver documentation, connect transceiver
network media connector to the network media.

USING DROP CABLE

NOTE: In a coax thicknet installation, each 10BASE-5 cable end
must be terminated using a 50 ohm terminator. Additionally, the
10BASE-5 segment must be grounded to “earth ground” at one end.

1.

Locate AUI uplink adapter installed at E-FL-HB-0x00 back. (See
page 4.) 

2.

Locate or build IEEE 802.3 compliant AUI drop cable. (See
page 14.)

3.

Connect AUI drop cable male connector to female AUI (DTE)
connector on E-FL-HB-0x00

OPERATION 

Use the status LEDs to monitor E-FL-HB-0x00 operation in the network. 

E-FL-0X00 HUB INDICATORS

P(o)W(e)R

Steady LED indicates E-FL-HB-0x00 is
connected to external AC power.

COL(lision)

Flashing LED indicates network collisions.

B(ACK)B(ONE) INDICATORS

STAT(us)

Steady LED indicates, for network
connection, a valid link and no partition or
isolation.

One (1) continuous, flashing blink indicates

network link is down.

Two (2) continuous, flashing blinks indicate
reception of Far End Fault (if fiber uplink
adapter is installed and LINKAlert™ is
enabled) OR port is partitioned (if AUI or
BNC or fiber uplink adapter with
LINKAlert™ not enabled is installed).

ACT(ivity)

Flashing LED indicates reception of network
data packet(s).

10BASE-FL INDICATORS

STAT(us)

Steady LED indicates, for each port, a valid
link and no partition or isolation.

One (1) continuous, flashing blink indicates

link is down.

Two (2) continuous, flashing blinks indicate
port is partitioned.

ACT(ivity)

Flashing LED indicates, for each port,
reception of data packet(s).

STAT

10BASE-FL

1

2

3

4

5

6

7

8

PWR

COL

ACT

BB

STAT

10BASE-FL

1

2

3

4

5

6

7

8

PWR

COL

ACT

BB

1

3

2

4

5

7

6

8

STAT

10BASE-FL

1

2

3

4

5

6

7

8

PWR

COL

ACT

BB

1

3

2

4

5

7

6

8

50

 Terminator

Earth Ground

50

 Terminator

Summary of Contents for E-FL-HB-0400

Page 1: ...imits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European...

Page 2: ...DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model E FL HB 0x00 Series Unmanaged Fiber Hub Part Number E FL HB 0800 E FL HB 0800 SC E FL HB 0400 E FL HB 0400 SC Regulation EMC Directive 89 336 EEC Purpose To declare that the E FL HB 0800 or E FL HB 0400 to which this declaration refers is in conformity with the following standards EMC CI...

Page 3: ... Coaxial RG58 ThinNet Impedance 50 Ω 10 MHz Mutual Capacitance 24 pF ft 20 10 MHz Maximum Cable Length 185 meters 610 feet Maximum number network connections 30 Minimum distance between connections 0 5 meters 1 6 feet Terminate 10BASE 2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground AUI 10BASE 5 Cable Specifications 10BASE 5 CABLE...

Page 4: ...t against E FL HB 0x00 chassis 5 Secure backbone uplink adapter by installing retained screws through backbone uplink adapter into E FL HB 0x00 chassis 6 Is the B ack B one ACT ivity LED illuminated NO Disconnect and reconnect the backbone cable to restart the initialization process Restart the attached network device to restart the initialization process Contact Technical Support 800 260 1312 YES...

Page 5: ...LINKAlert is NOT enabled the port is partitioned investigate the device at the far end of the link If the fiber backbone adapter plate is installed and LINKAlert IS enabled determine and correct the cause of the Far End Fault Contact Technical Support 800 260 1312 NO Continue at step 6 Install E FL HB 0x00 at Site WARNING During the site installation handle the E FL HB 0x00 in such a way that the ...

Page 6: ...00 OPERATION Use the status LEDs to monitor E FL HB 0x00 operation in the network E FL 0X00 HUB INDICATORS P o W e R Steady LED indicates E FL HB 0x00 is connected to external AC power COL lision Flashing LED indicates network collisions B ACK B ONE INDICATORS STAT us Steady LED indicates for network connection a valid link and no partition or isolation One 1 continuous flashing blink indicates ne...

Page 7: ...ion within acceptable bounds NOTE In a coax thinnet installation the first and last device in the daisy chain must be terminated using a 50 ohm terminator Additionally the 10BASE 2 segment must be grounded to earth ground at one end To connect to 10BASE 2 network 1 Locate BNC uplink adapter installed at E FL HB 0x00 back See page 4 2 Locate or build IEEE 802 3 compliant 10BASE 2 cable and male BNC...

Page 8: ... Locate or build 10BASE FL compliant two stranded fiber cable with appropriate male TX to RX connectors installed at both ends 2 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on front of one hub 3 Connect male TX and RX cable connectors at other end of cable to RX and TX connectors respectively on front of second hub Connect E FL 0x00 Hub t...

Reviews: